VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
1-2
Features
Hardwire and Optional Expansion Zones
•
Provides nine hardwire zones.
•
Supports up to 16 2-wire smoke detectors on zone 1.
•
Automatically resets 4-wire smoke detectors using the J7 output when a code + off is entered.
•
Triggers the built-in sounders on other hardwired smoke detectors if one smoke detector annunciates an alarm. This
feature requires a 4204 Relay Module.
•
Provides tamper supervision on the hardwire zones.
•
Supports up to 241 additional expansion zones (119 for the VISTA-128BPT) using a built-in polling (multiplex) loop.
•
Supports up to 249 wireless zones (127 for the VISTA-128BPT) (fewer if using hardwire and/or polling loop zones).
UL
The 5881ENHC RF Receiver, 5869 Holdup Switch Transmitter and 5817CB Wireless Commercial Household
Transmitter are listed for UL Commercial Burglary applications. All other RF receivers and transmitters are not listed
for UL Commercial Burglary applications.
ULC
Wireless devices are not ULC Listed and cannot be used for ULC Installations.
•
Can program burglary zones as silent in the alarm condition (alarm output is silent and the keypad does not display
or sound the alarm).
•
Provides three keypad panic keys: 1 +
∗
(A),
∗
+ # (B), and 3 + # (C).
UL
Use of Remote Interactive Service (Total Connect) is not permitted in UL installations.
•
NOTE:
If using Total Connect Remote Interactive Services, the virtual keypad must be assigned to a burglary
partition, and the GOTO feature (program field 2
∗
18) must be “0” (disabled) for partition 1 (the fire partition) so that
the Fire system cannot be accessed remotely. This is the system default setting.
•
Anti-Mask is used if a zone type 04 (interior) or 10 (interior with delay) and input type 06 (serial poll) are selected.
The trouble report code is used to report the masking.
•
A Smart contact option that may be selected for devices that support this feature such as the 5193SDT Smoke
Detector or PIRs.
•
Battery sensing hardware that can sense when the battery voltage is too low and prevents deep discharging from
not occurring.
Peripheral Devices
•
Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.).
•
Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up to 32), as well as system
zones (RF receivers and keypad panics).
•
Provides 96 outputs using 4204 Relay Modules and V-Plex Relay Modules that can activate outputs in response to
system events (alarm condition), at a specific time of day, at random times, and manually using the #70 Relay
Command Mode.
•
Supports the ADEMCO 4146 Keyswitch on any one of the system's eight partitions.
Arming/Disarming and Bypassing
•
Can arm the system with zones faulted (Vent Zone). These zones are automatically bypassed and can be
programmed to automatically unbypass when the zone restores.
•
Can arm with entry/exit and interior type zones faulted (Arm w/Fault). These zones must be restored before the exit
delay expires, otherwise an alarm is generated.
UL
•
Vent zones cannot be used in UL installations.
•
You
must disable
the Force Arm option (used in conjunction with the Arm w/Fault option), in UL installations.
ULC
You
must disable
the Force Arm option (used in conjunction with the Arm w/Fault option), in ULC Installations.
•
Provides global arming capability (ability to arm all partitions the user code has access to in one command).
Содержание VISTA-128BPT
Страница 2: ......
Страница 46: ......
Страница 56: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide 4 10 ...
Страница 88: ...V128BPT V250BPT Installation and Setup Guide 8 2 ...
Страница 104: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide C 2 ...
Страница 112: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Glossary 6 ...
Страница 118: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Index 6 ...
Страница 120: ...For the latest warranty information please go to www honeywell com security hsc resources wa ...
Страница 121: ...NOTES ...
Страница 122: ...NOTES ...
Страница 123: ...NOTES ...