Section 3 – Installing the Control
3-19
Installing a Remote Keyswitch
A UL-Listed remote keyswitch, such as the ADEMCO 4146, can be used for remote arming/disarming of the burglary
portion of the system and for silencing alarms. The keyswitch can operate in only one particular partition.
ULC
Remote Arming is not a ULC Listed feature.
The keyswitch is wired across zone 7. This zone is no longer available as a protection zone. Be sure to program Zone 7
with a response type (e.g., type 10).
Operation
•
A momentary short across zone 7 arms the partition in the AWAY mode, and a short held for more than 10 seconds
arms the partition in STAY mode 1. A subsequent short disarms the partition.
•
The keyswitch LEDs indicate the partition’s status (see table below).
•
A momentary short across Zone 7 silences alarm bell and keypad sounds, and disarms the system if it was armed. A
subsequent short across Zone 7 clears the alarm memory indication and resets 2-wire smoke detectors (if used).
LED Indications
Green
Red
Indication
On
Off
Disarmed & Ready
Off
Off
Disarmed & Not Ready
Off
On Steady
Armed Away
Off
Slow Flash
Armed Stay
Off
Rapid Flash
Alarm Memory
The keyswitch reports as user 0, if Open/Close reporting is enabled in field
∗
40.
Keyswitch Tamper Operation
The tamper switch need not be used for fire or UL Household Burglary installations. For UL Commercial Burglary
installations, the tamper switch must be wired to a zone (zone 7 in
Figure 3-20
).
Program that zone for Day Trouble/Night Alarm (response type 5). When the keyswitch is removed from the wall, the
tamper switch opens, causing an alarm or trouble on the zone. This also causes the control to disable keyswitch
operation until the tamper is restored and the associated partition is disarmed.
Wiring for the Remote Keyswitch
To install the ADEMCO 4146 keyswitch, perform the following steps:
Step
Action
1
Connect the ADEMCO 4146 to the panel as shown in
Figure 3-20
.
2
If you are using the tamper, make sure it is connected to a zone.
2K ELOR
2K ELOR
TAMPER SWITCH
(CONTACTS CLOSE WHEN
SWITCH DEPRESSED).
LOCK SWITCH
(NORMALLY OPEN)
+
TO J7 / OUT 2
TO J7 / OUT 4
TO AUX POWER
(TERMINAL 6)
ZONE
ZONE
TO ZONE 7 (+)
(TERMINAL 20)
YELLOW
WHITE
GREEN
(READY)
RED
(ARMED)
RED
BLACK
820
ohms
820
ohms
J7_keyswitch
Figure 3-20: Remote Keyswitch Wiring
Содержание VISTA-128BPT
Страница 2: ......
Страница 46: ......
Страница 56: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide 4 10 ...
Страница 88: ...V128BPT V250BPT Installation and Setup Guide 8 2 ...
Страница 104: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide C 2 ...
Страница 112: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Glossary 6 ...
Страница 118: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Index 6 ...
Страница 120: ...For the latest warranty information please go to www honeywell com security hsc resources wa ...
Страница 121: ...NOTES ...
Страница 122: ...NOTES ...
Страница 123: ...NOTES ...