EXPERION MX RAE STATION LAYOUT
6510020335
84
NOTE
During normal scanning of the product throughout the shift, the scanner
stops periodically and standardizes. This function verifies sensor
accuracy. At least once every 24 hours the scanner performs a
background check that allows the sensor to measure the background
electrical noise to be filtered from all normal measurements and
standardized readings. After completing standardization or background
measurements the scanner automatically resumes product
measurement.
Single Pointing the Heads
1.
Check the status of the scanners on the application status zone.
2.
Select the scanner you want to send to Single Point from the drop-down menu.
3.
Select the Single Point Position Box and a numeric keypad appears.
4.
Enter the position you want the scanner to stop at through the keypad.
5.
Click the
Single Point Request
button. The scanner moves towards the slice position,
slows down when it nears the position, and finally stops at the position. Sensor
measurements begin updating.
6.
The scanner can be switched from single point to either Scan or Offsheet by pressing
the appropriate button on the Scan Control Panel.
Fix Pointing the Heads
The procedure to Fixed Point the heads is same as the procedure for Single Point, except
that the
Fixed Point
request button is used instead of the
Single Point
request button.
When a scanner is in Fixed Point, the advanced Fixed Point analysis page is activated. This
allows the scanner to sample pure MD measurements at up to 2048 Hz. It is used to
identify MD disturbances.
4.2.5
Scan
The Scan
button is used to start scanning on all scanners.
1.
Check the status of the scanner at the bottom of the display.
2.
If the status is
OFFSHEET
, simply click the
SCAN
button in the Station Toolbar.
3.
If the status is
OFFLINE
, this means the scanner was last sent offsheet from the
Offsheet buttons at the scanner. To scan the heads you must press the SCAN button
at the scanner. This is a safety feature. Alert any personnel in the vicinity of the
Содержание Experion MX
Страница 1: ...Experion MX RELEASE 702 1 Operators Guide 6510020335 Rev 02 May 2019 ...
Страница 7: ...6510020335 7 8 NOTICES 168 ...
Страница 20: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 20 Fig 15 Cable End Voltage Zones ...
Страница 21: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 21 Fig 16 Distant End Voltage Zones ...
Страница 124: ...PROCESS INFORMATION DISPLAYS 6510020335 124 Fig 105 Profile Display ...
Страница 159: ...PROCESS INFORMATION DISPLAYS 6510020335 159 Fig 148 Precision Platform 4000 01 Scanner ...
Страница 160: ...PROCESS INFORMATION DISPLAYS 6510020335 160 Fig 149 Precision Platform 4000 20 21 Scanner ...