10.2 List of status messages
Message Status Name
Description, Procedure
a) Alarms, faults
1
StSy
Restart
If this message appears whilst in operation, the device is faulty.
Contact the Honeywell Technical Assistance Center.
1
StSy 2
Data error
An error was detected during the cyclic check of the data subject
to calibration regulations.
Contact the Honeywell Technical Assistance Center.
1
St.4
Vm-Alarm
No volume was recorded at the used input for conversion.
(Automatic switching to a second pulse generator as described in
(p. 27) is not configured).
1
St.5
C-fact. err.
The conversion factor could not be calculated as the measured
gas temperature was outside 100°C to +100°C or no usable
compressibility ratio factor was available.
1
St.6
T Alarm Lim.
The gas temperature measured is outside acceptable limits.
The limit values can be changed when putting the device into
operation in the presence of a calibration officer (
Operating
1
St.7
p Alarm Lim.
The measured gas temperature is outside the permissible limits.
The limit values can be changed when putting the device into
operation in the presence of a calibration officer (
Operating
1
St.8
K-val. error
The compressibility ratio factor could not be calculated as no valid
real gas factor could be determined.
1
St.9
z-fact. err.
The real gas factor could not be calculated.
At least one of the gas analysis values Ho.n, CO2, H2, rhon, is
outside the permissible range.
2
St.4
Vm Inp. error
No volume at measurement conditions was recorded at the
connected encoder on input 1 for 40 seconds (with external power
supply) or for one measurement cycle + 1 second (battery
powered).
2
St.5
T Inp. error
The gas temperature cannot be measured due to a fault.
Contact the Honeywell Technical Assistance Center.
2
St.6
p Inp. error
The gas pressure cannot be measured due to a fault.
Contact the Honeywell Technical Assistance Center.