For any further individual settings and tests required, press "
Navigation
" on the left-hand side and
then "
Parameterize online
" at the bottom of the navigation window.
i
All the values listed in enSuite under "
Parameters
" can be found on the "
Serv.
" display tab of the
EK280 under the same path.
i
ATTENTION!
Should your Ethernet card already have been parameterized with corresponding
network data, the default settings (e.g. port, IP address, sub net mask) must be deleted from the
initialization string in order to prevent them being accidentally overwritten. You will find the
modem initialization string under "
Parameters
" > "
Interfaces
" > "
Terminal interface
".
7.4.10.2 Parameterization of the FE260-integrated Ethernet adapter with enSuite
i
For parameterization of the Ethernet adapter in the FE260 for operation with a quantity converter
EK280, a connection cable is required for the optical interface as well as the enSuite program,
which can be downloaded free of charge from
The Ethernet adapter in FE260 is basically parameterized at the Honeywell factory, so that at the time of
commissioning on site only the following, application-specific parameters need to be set.
−
IP address
−
Gateway address
−
Subnet mask
−
TCP-Port
These parameters may be set as follows in the Ethernet adapter:
−
Make sure that the FE260 is switched off.
−
Start enSuite and establish the communication link to theEK280 via the optical interface.
(
3.1 Setting up the communication link to the EK280 via optical interface
−
Select "
Navigation
" on the left-hand side of the enSuite window and then "
Parameterize online
" at
the bottom of the navigation window.
−
In the top of the device window open the path "
Parameters
" > "
Interfaces
" by clicking on the relevant
plus signs, and then select "
Call time windows
".
−
Make sure that time windows 5 and 6 are closed.
−
In the path "
Parameters
" > "
Interfaces
" choose the option "
Terminal interface
"
.
−
Select the menu item "
Ethernet
"
.
−
Now enter your individual address parameters (IP, Subnet Mask, Gateway, Port) in the appropriate
parameter fields. Where necessary, you may require permission from your network administrator at