Press the button "
Parameterize
".
−
Wait until the message "Parameterization OK" is displayed:
−
Terminate the "ModemIni" program.
−
Switch off the power to EM260.
−
Detach the USB parameterization cable from the EM260.
−
Now fit the jumper J1 in the uppermost position (
Operating Instructions for the EM260, chapter 10,
"Jumper").
−
Close the housing of the WM260.
Switch on the mains power supply of the EM260 again. The plug symbol in the Main Menu of the EK280
shows the external supply.
7.3.2.3 Retrieving data with enSuite
7.1.4.3 Retrieving data with enSuite
(p. 64)