9.1.1 Archive content
Pos. Address Display
Description
Retrievable
1
1
01:01F8 GONo
Global Block number
S
2
03:0A20 ABNo
Archive Block number
A + S
3
01:0400 Time
Date and time
A + S
4
02:0300 Vb
Volume at base conditions
A + S
5
-
∆
Vb
Meter progress Volume at base conditions
A
6
02:0302 VbT
Volume at base conditions total
A + S
7
-
∆
VbT
Meter progress Volume at base conditions total
A
8
04:0300 Vm
Volume at measurement conditions
A + S
9
-
∆
Vm
Meter progress Volume at measurement conditions
A
10
04:0302 VmT
Volume at measurement conditions total
2
A + S
11
-
∆
VmT
Meter progress Volume at measurement cond. total
A
12
19:0161 p.MP
∅
Pressure mean value of last meas period
A + S
13
15:0161 T.MP
∅
Temp. interval mean value
A + S
14
23:0161 K.MP
∅
Mean value K of last meas period
A + S
15
25:0161 C.MP
∅
Mean value C of last meas period
A + S
16
02:0110 St.2
Instance-Status 2 (incl. Vn)
A + S
17
04:0110 St.4
Instance Status 4 (incl. Vb)
A + S
18
07:0110 St.7
Instance Status 7 (incl. p)
A + S
19
06:0110 St.6
Instance Status 6 (incl. T)
A + S
20
02:0100 StSy
System status
A + S
21 03:0A23 ErReg
Error register
A
22 03:0A22 Ev
Event causing data line to be archived
A + S
23 03:0A21 Check
Check sum result ( „CRC OK“ or „Error“)
A + S
The values can be retrieved in accordance with the information in the table via D = display and/or
I = interface.
When using an encoder then the original operating volume "Vo" (01 240) can also be set.
The counter progress compared to the respective previous entry is denoted with a "
∆
". Normally it is a flow
(consumption) in this case within a measurement period. This, however, does not apply when an archive row
is entered due to a particular event (e.g. setting the clock or a counter, appearance of an important status
message). The meter reading flashes with the meter progress to point out this feature to the user (for further
information, refer to the instruction manual “usage as a registration device”).
9.1.2 Memory capacity
Based on factory settings, the archive contains 9504
data rows, which corresponds to a memory capacity of
approx. 13 months with a measurement period of 60 minutes.