EK280
Application Manual
13
2.3.2 Freeze display ("Freeze Display")
This function can be used for example to record multiple measurement values, for which the time stamp is
significant.
All currently displayed values are "frozen", i.e. cached for subsequent display in place of the real time values,
until the display is unfrozen.
Measurement is unaffected and continues in the background.
The state is indicated by a blinking symbol ("frozen") in the status bar. Pressing any key unfreezes the
display and re-displays the real time values.
Fig. 3: "frozen" display
2.3.3 Clear status register ("Clear Status R.")
The status register is cleared (
i
Deleting statuses can only be carried out if the administrator or calibration lock is open.
If both locks are closed then the context menu is left without deleting the status register.
2.4 Special commissioning function
2.4.1 Device software and checksum
−
Move the cursor under tab "
Serv.
" to
"Identification" > "Volume Converter" > "Vers"
or
"Chk".
−
The checksum
"Chk"
can be recalculated for verification purposes by pressing the ENTER key.
2.4.2 Clear volumes and archives ("Clr.V")
i
The
"Clr.V"
functions described here delete all volume counters and
all
archives and logbooks.
−
So that all volume counters and
all
archives and logbooks are deleted from the device, open the
calibration lock as described in the EK280 Operating Instructions.
−
Move the cursor in tab
"Serv."
to
"Edit and delete” > "Clr.V".