1-1
S E C T I O N 1
General Description
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
General Description
The VISTA-120 is an 8-Partition alarm control panel that supports up to 128 zones using basic wired, polling loop, and
wireless zones. In addition, the control offers relay control, access control capability, and scheduling capabilities for
automating system functions. The major system features are outlined below.
New Features
Margin bars are included to indicate which features are new for this version of the VISTA-120.
This version of the VISTA-120 has enhanced features not found in the prior version.
•
Supports up to 250 cadholders and up to 15
VistaKey modules (15 access points), which are
used for access control. It is a single-door access
control module
•
Supports “linking” together up to 8 control panels
via VA8200 Panel Linking Modules. This allows
users to access and control from a keypad another
control panel
•
Expansion of the event log capacity from 224 to 512
events
•
Support for intelligent polling loop motion sensors
that will send more data on the bus
•
Expansion of the number of alpha custom words
supported for zone descriptors from 20 to 60 words
•
Support of the Quest 2260SN polling loop type PIR.
These devices must be programmed with a “YES”
at the “Smart Contact” prompt in
Zone
Programming
in the
#93 Menu Mode
•
Support of the Symphony (AUI) Touchscreen
keypad. See the Symphony instructions for it’s
installation and operation
•
Support for FSA-8 (8 zones) and FSA-24 (24 zones)
LED annunciators.
Basic Wired Zones
Provides 9 basic wired zones:
•
EOLR supervision (optional for zones 1-8)
supporting N.O. or N.C. sensors (zone 1 via red
jumper on PC board above terminal 10)
•
Individually assignable to one of 8 partitions
•
Up to 16 2-wire smoke detectors on zone 1
•
4-wire smoke or heat detectors on zones 1-8
•
Up to 50 2-wire latching glassbreak detectors on
zone 8
Wireless Expansion
Supports up to 128 wireless zones using
5881EN/5882EU/5882EUH/5882AP type RF Receiver
(less if using basic wired and/or polling loop zones).
Wireless zones have the following characteristics:
•
Supervised by control panel for check-in signals
(except certain non-supervised transmitters)
•
Supervised for low battery condition
•
Cover removal tamper protection for
5800/5800EU/5800H/5800AP series supervised
transmitters
•
Wall removal tamper protection for 5800EU/5800H
series supervised transmitters
•
Individually assignable to one of 8 partitions
For specific information regarding number of
wireless zones supported by each RF
receiver, see
Wireless Expansion
later in
this manual.
Polling Loop Expansion
Supports up to 119 additional wired zones using a built-
in polling (multiplex) loop interface. Current drain can
total up to 128mA. Polling loop zones have the
following characteristics:
•
Must use RPM (Remote Point Module) devices
•
Supervised by control panel
•
Individually assignable to one of 8 partitions
Peripheral Devices
Supports up to 32 addressable devices, which can be
any combination of 6139/6164/5839EU/5839H keypads,
RF receivers (5881EN/5882EU/5882EUH/5882AP),
relay modules (4204), Fire System Annunciators (FSA-
8, FSA-24), panel linking module (VA8200) and the
4286 VIP module or TeleCommand. Peripheral Devices
have the following characteristics:
•
Terminated at the Keypad Port terminals on the
control panel (except for wireless 5839EU/5839H)
•
Each device set to an individual address
(physically) according to the device's instructions
•
Each device enabled in the system using the
Device
Programming Mode
Содержание ADEMCO VISTA-120
Страница 2: ...ii ...
Страница 18: ...VISTA 120 Installation and Setup Guide 2 8 ...
Страница 70: ...VISTA 120 Installation and Setup Guide 5 16 ...
Страница 88: ...VISTA 120 Installation and Setup Guide 7 4 ...
Страница 90: ...VISTA 120 Installation and Setup Guide 8 2 ...
Страница 100: ...VISTA 120 Installation and Setup Guide A 2 ...
Страница 104: ......
Страница 106: ......
Страница 113: ......