Section 3 – Installing the Control
3-25
Connecting the AC Mains Transformer
This product uses the 1361 Transformer in 110 VAC
markets. If you are using powerline carrier devices, use
the 4300 Transformer. In Australia, use the XF10 and
in Europe, use the XM10E in addition to the normal
16.5VAC/40VA output transformer.
NO CONNECTION
TRANSFORMER
16.5VAC, 40VA
ADEMCO No.1361
or 4300, XM10E, or
XF10 if X-10 DEVICES
WILL BE USED.
Connect to
24hr. source
of AC mains
1
2
3
RED (+)
BLK (
–
)
Connect to
12VDC, 4AH
or 12VDC, 7AH
GEL CELL
BATTERY
CHARGING
VOLTAGE
13.7 VDC
NOTE:
WHEN POWERING UP
THE PANEL, PLUG THE
TRANSFORMER IN BEFORE
CONNECTING THE BATTERY.
BATTERY
TABS
PRIMARY POWER
Supplied by a
transformer which
is rated at
16.5VAC, 40VA.
Caution must be
taken when wiring
this transformer to
the panel to guard
against blowing the
fuse inside the
transformer (non-
replaceable).
Figure 3-37. AC Mains and Battery Connections
Wiring the 1361 Transformer
Wire a 1361 110VAC Transformer (not supplied) to
terminals 1 and 2 on the control panel as shown in
Figure 3-37
. In 220VAC regions, use a 16.5VAC/40VA
output transformer.
Wiring the 4300/XF10 Transformers
Wire the 4300 Transformer as follows:
1.
Connect terminals 1 and 3 (AC) and terminal 2
(Ground) of the 4300 transformer interface to
control panel terminals 1, 2, and 30, respectively,
see
Figure 3-38
.
2.
Run a 6-conductor cable between the 4300 and the
panel. Splice this cable to a 4142TR cable as shown
below. Note that the white and yellow wires of the
4142TR
must be spliced
together.
In Australia, use the XF10 and in Europe, use the
XM10E in addition to the normal 16.5VAC/40VA output
transformer. See
Figure 3-39
.
X-10 Powerline Carrier devices are either plugged into
standard AC outlets or wired into the AC electrical
system by a licensed electrician, depending on the type
of device used. They respond to "on" and "off"
commands sent from the panel, through the
4300/XF10/XM10E, to the receiving devices.
1
2
3
4
5
6
7
8
9
GROUND
GROUND
OUT 6
IN 2
GROUND
IN 3
GROUND
OUT 5
J8 CONNECTOR
BLACK
BLUE
BROWN
GREEN
RED
WHITE
YELLOW
GRAY
VIOLET
4142TR CABLE
1
2
3
4
5
6
TB1
-1
TB1
-30
TB1
-2
AC
Earth
Ground AC
Sync Data Com
4300 TRANSFORMER/INTERFACE
115VAC
60Hz
Figure 3-38. 4300 Transformer Connections
1 2 3 4 5 6 7 8
9
GREY
YELLOW
WHITE
RED
GREEN
BROWN
BLUE
BLACK
J8 CONNECTOR
VIOLET
4142TR CABLE
W2
GROUND
IN 3
GROUND
OUT 5
OUT 6
GROUND
GROUND
30
2
1
TRANSFORMER
16VAC IN
EARTH
GROUND
SYNC
DATA
COMMON
220/230VAC
50HZ
YELLOW
BLACK
RED / GREEN
TRANSFORMER MODULAR
CORD COLORS
Figure 3-39. XF10 Transformer Connections
Earth Ground Connections
In order for the lightning transient protective devices in
this product to be effective, the designated earth ground
terminal (terminal 30), must be terminated in a good
earth ground. We recommend using 1.3mm diametre
copper wire run at a maximum length of 7.5m. The
following are examples of good earth grounds available
at most installations:
•
Metal Cold Water Pipe:
Use a non-corrosive
metal strap (copper is recommended) firmly
secured to the pipe to which the ground lead is
electrically connected and secured.
•
AC Power Outlet Ground:
Available from 3-
prong power outlets only. To test the integrity of
the ground terminal, use a three-wire circuit tester
with neon lamp indicators.
Calculating the Battery Size Needed
In the event of an AC power loss, the Control panel will
still operate for a period of time (time period varies
depending on size of battery used) because the control
has a back-up, rechargeable (sealed) lead acid battery.
ADEMCO 467 (12V, 4AH) and ADEMCO 712BNP 12V,
7AH batteries are recommended.
The standby battery is automatically tested every 4
minutes for 13 seconds (or every 50 seconds for 1.5
seconds, as a function of program selection) and every
24 hours for 10 minutes, beginning 24 hours after
exiting programming mode.
Use the following worksheets to calculate the total
current drain on the control panel.
Содержание ADEMCO VISTA-120
Страница 2: ...ii ...
Страница 18: ...VISTA 120 Installation and Setup Guide 2 8 ...
Страница 70: ...VISTA 120 Installation and Setup Guide 5 16 ...
Страница 88: ...VISTA 120 Installation and Setup Guide 7 4 ...
Страница 90: ...VISTA 120 Installation and Setup Guide 8 2 ...
Страница 100: ...VISTA 120 Installation and Setup Guide A 2 ...
Страница 104: ......
Страница 106: ......
Страница 113: ......