Section 5 - Data Field Descriptions
5-3
*21
Prevent Fire Timeout
0
= disable (timeout)
1
= enable (no timeout)
If enabled, there is no timeout of the alarm sounder duration for all fire zones,
regardless of partition, so that fire sounding continues until the system is
reset.
If disabled, (timeout) the normal burglary sounder duration (field
✳
13) applies
to fire alarms.
*22
Keypad Panic Enables (partition-
specific)
0
= disable
1
= enable
If enabled, the keypad panics (zones 995, 996, and 999) may be used in this
partition. There are 3 entries in this field, one for each panic.
*23
Multiple Alarms (partition-specific)
0
= disable
1
= enable
If enabled, allows more than one alarm sounding for a given zone during an
armed period.
NOTE:
that multiple alarm soundings will not occur more frequently than
allowed by the programmed alarm sounder duration. This has no impact on
the number of communication messages transmitted.
*24
Ignore Expansion Zone Tamper
0
= disable (tamper detection)
1
= enable (no tamper detection)
If disabled, the system monitors the tampers on expansion zones.
NOTE:
Only applicable to certain polling loop sensors with tamper switches or
5800 Series transmitters.
*25
Burglary Trigger for Response Type
8
0
= disable
1
= enable
If enabled, allows triggering of the voltage output on Pin 3
of the J7 header to
include zone response type 8 (24-hr. auxiliary).
*26
Intelligent Test Report
0
= disable
1
= enable
If enabled, no test report is sent if any other type of report was sent since the
last test report.
If disabled, test reports are sent at the set intervals, regardless of whether or
not any other report has been sent..
*27
Test Report Interval
Enter
001-999
for the test report interval in
hours.
Enter
000
for test reporting.
If a test report is desired, enter a test code in field *81 and *82. Set first test
report time in field *83.
*28
Power-Up in Previous State
0
= disable
1
= enable
If enabled, the system, upon power-up, reverts to its status prior to a complete
power loss.
If disabled, the system always powers up in a disarmed state.
NOTE:
Neither authority level 0 nor 5 can be used to disarm the system if the
control powers up armed.
*29
Quick Arm (partition-specific)
0
= disable
1
= enable
If enabled, allows arming of the burglary system in AWAY, STAY, INSTANT,
or MAXIMUM mode by using the [#] key instead of the user code.
When armed, the system reports closing as User 0 if Open/Close reporting for
User #2 (typically a Master level user) was enabled for a given partition.
If Quick Arm is used, the Installer Code and Authority Level 5 codes cannot
disarm the system.
Multifrequency or Pulse Dial
0
= pulse
1
= multifrequency
Select the dialing method for the system
If you select multifrequency, make sure the subscriber has requested and is paying for multifrequency service. Note
that whether or not multifrequency dialing for call placement is permitted, communication by the use of DTMF
signaling (ADEMCO High Speed, 4 + 2 Express, ADEMCO Contact ID) will still take place. See field 1*33 for
Multifrequency w/decadic dial pulse backup
*30
*31
PABX Access Code
Enter
00-09; B-F (11-15)
This field is used to enter up to four 2-digit numbers representing the prefix
needed to obtain an outside telecom line. If not required, enter nothing and
proceed to next field.
FIELD
TITLE and DATA ENTRIES
EXPLANATION
Содержание ADEMCO VISTA-120
Страница 2: ...ii ...
Страница 18: ...VISTA 120 Installation and Setup Guide 2 8 ...
Страница 70: ...VISTA 120 Installation and Setup Guide 5 16 ...
Страница 88: ...VISTA 120 Installation and Setup Guide 7 4 ...
Страница 90: ...VISTA 120 Installation and Setup Guide 8 2 ...
Страница 100: ...VISTA 120 Installation and Setup Guide A 2 ...
Страница 104: ......
Страница 106: ......
Страница 113: ......