VISTA-120 Installation and Setup Guide
6-8
Note that these codes are independent of the relay
codes programmed during
Output Programming
in the
#93 Menu Mode
located in the Programming Guide.
Relay Commands
Action Code
Action
Action Specifier
01
Relay On
Relay #
02 Relay
Off
Relay #
03
Relay Close for 2 seconds
Relay #
04
Relay Close XX minutes (set
in field 1*74)
Relay #
05
Relay Close YY seconds (set
in field 1*75)
Relay #
06
Relay Group On
Relay Group #
07
Relay Group Off
Relay Group #
08
Relay Group Close for 2
seconds
Relay Group #
09
Relay Group Close XX
minutes (set in field 1*74)
Relay Group #
10
Relay Group Close YY
seconds (set in field 1*75)
Relay Group #
Arm/Disarm Commands
Action Code
Action
Action Specifier
20 Arm-STAY
Partition(s)
21 Arm
AWAY
Partition(s)
22 Disarm
Partition(s)
23
Force Arm STAY (Auto-
bypass faulted zns)
Partition(s)
24
Force Arm AWAY (Auto-
bypass faulted zns)
Partition(s)
25 Arm
INSTANT
Partition(s)
26 Arm
MAXIMUM
Partition(s)
The auto-arm warning (field 2*06) applies when
using Time-Driven events to auto-arm.
Temporary schedules do not override an auto-
arming or auto-disarming programmed in Time-
Driven events.
The auto-arming time period cannot be extended
using the Installer Code + #82 Mode.
Bypass Commands
Action Code
Action
Action Specifier
30 Auto
bypass
– Zone list
Zone list #
31 Auto
unbypass
– Zone list
Zone list #
Open/Close Time Periods
Action Code
Action
Action Specifier
40
Enable Opening Time Period
by partition
Partition(s)
41
Enable Closing Time Period
by partition
Partition(s)
42
Enable Access Time Period
for access group
Access Group
Access Control Commands
Action Code
Action
Action Specifier
55
Access Point Grant
Access Point #
56
Access Point Grant with
Override
Access Point #
57
Access Point Protect
Access Point #
58
Access Point Bypass
Access Point #
59
Access Point Lock
Access Point #
60
Access Point Exit
Access Point #
61
Access Point Group Grant
Group #
62
Access Point Group Grant
with Override
Group #
63
Access Point Group Protect
Group #
64
Access Point Group Bypass
Group #
65
Access Point Group Lock
Group #
66
Access Point Group Exit
Group #
67
Access Point Partition Grant
Partition #
68
Access Point Partition Grant
with Override
Partition #
69
Access Point Protect by
Partition
Partition #
70
Access Point Bypass by
Partition
Partition #
71
Access Point Lock by
Partition
Partition #
72
Access Point Exit by Partition
Partition #
73
Access Point Trigger On
Trigger #
74
Access Point Trigger Off
Trigger #
77
Access Point Group Enable
Group #
78
Access Point Group Disable
Group #
3.
Enter the desired activation time
(when the
action is to take place). Select from:
Activation
Time
Description
01
Beginning of time period.
02
End of time period.
03
During time period only (on at beginning of
time period, off at end).
For example, if bypass is selected to activate
during the time period, zones in a zone list
are bypassed at the beginning of the time
period and unbypassed at the end of the time
period.
04
Beginning and end of time period (e.g., a
coffee break buzzer). In this example, if relay
pulse is selected, the relay pulses for 2
seconds at the beginning of the time period,
signaling the beginning of the coffee break.
At the end of the time period it pulses again,
signaling the end of coffee break.
Содержание ADEMCO VISTA-120
Страница 2: ...ii ...
Страница 18: ...VISTA 120 Installation and Setup Guide 2 8 ...
Страница 70: ...VISTA 120 Installation and Setup Guide 5 16 ...
Страница 88: ...VISTA 120 Installation and Setup Guide 7 4 ...
Страница 90: ...VISTA 120 Installation and Setup Guide 8 2 ...
Страница 100: ...VISTA 120 Installation and Setup Guide A 2 ...
Страница 104: ......
Страница 106: ......
Страница 113: ......