Section 3 – Installing the Control
3-13
1
2
3
4
5
6
7
8
9
GROUND
GROUND
OUT 6
IN 2
GROUND
IN 3
GROUND
OUT 5
J8 CONNECTOR
AT CONTROL
BLACK
BLUE
BROWN
GREEN
RED
WHITE
YELLOW
GRA
Y
VIOLET
4142TR CABLE
COM
SYNC
DATA
1 2 3 4
XM10E
POWERLINE INTERFACE
MODULAR PHONE CORD
1 - BLACK
2 - RED
3 - GREEN
4 - YELLOW
BLK
GRN
RED
YEL
RJ11 JACK
Figure 3-20. XM10E Modulator Connection
Installing the FSA Modules
The 8-zone LED Fire System Annunciator FSA-8 and
24-zone LED Fire System Annunciator FSA-24 enable a
fire response unit to identify quickly the point/zone of a
fire. These indicators may be used for other functions as
well, such as status indication. A maximum of 4 FSA
modules, in any combination, can be supported.
The FSA module will not operate until the
device address you have set the DIP switches
for is enabled in the control’s
Device
Programming in the #93 Menu Mode.
To install the FSA module, refer to
Figure 3-21
and
perform the following steps:
Step Action
1
Set the FSA’s DIP switches for a device
address from 08 to 23. See the module’s
instructions for the DIP switch table.
Do not use an address being used by another
device (keypads, RF receivers, etc.).
2
Mount the FSA module horizontally to a
duplex box (quad box for FSA-24).
3
Connect the module to the control’s keypad
terminals (6, 7, 8, and 9).
0 0 0 0 0
ECP Bus
Dip Switch
Optional
Keyswitch
Connection
SIDE
VIEW
All Switches shown
in Up position.
(ECP Address 23)
Terminal
Block
Connect to
Keypad
Terminals
Figure 3-21: Wiring the FSA Module
Installing 4101SN Relay Modules
The 4101SN V-Plex Single Output Relay Module is a
serial number polling loop output device. The 4101SN
features the following:
•
Form C relay contacts rated at 2A, 28VAC/VDC
with contact supervision.
The position of the relay is supervised, but not
the actual external contact wiring.
•
One class B/style B EOLR-supervised auxiliary
input zone.
•
Operating power and communication with control
panels via the V-Plex polling loop.
•
Electronics mounted in a small plastic case with
tamper-protected cover.
Connect the device to the polling loop, terminals 24 (+)
and 25 (-). Be sure to observe polarity
Содержание ADEMCO VISTA-120
Страница 2: ...ii ...
Страница 18: ...VISTA 120 Installation and Setup Guide 2 8 ...
Страница 70: ...VISTA 120 Installation and Setup Guide 5 16 ...
Страница 88: ...VISTA 120 Installation and Setup Guide 7 4 ...
Страница 90: ...VISTA 120 Installation and Setup Guide 8 2 ...
Страница 100: ...VISTA 120 Installation and Setup Guide A 2 ...
Страница 104: ......
Страница 106: ......
Страница 113: ......