VISTA-120 Installation and Setup Guide
3-14
Open/Close Trigger Setup
Output 1 may alternately be programmed to change
states when the system is armed in the away mode and
then disarmed. If field 1*46 is set to
1
, the output is set
high when the system is in the "disarmed" state.
It switches to "0" volts when the system is armed in the
"away" mode. This trigger will not change state unless
all
partitions are armed, and will change state again as
soon as one partition is disarmed.
Installing a Remote Keypad Sounder
Output 1 may alternately be programmed for a remote
keypad sounder. You may use an Amseco PAL 328N
piezoelectric sounder for installations where you want
the sounds produced by the keypad's built-in piezo
sounder to be duplicated in another location for one
partition. The panel will send all sounds remotely (i.e.
alarm, trouble, chime, entry/exit, etc.) except for the
short clicks associated with keypad key depression.
One application of this feature might be to produce
chime sounds in a location that is distant from the
panel's keypads. You can also accomplish this by using
relay outputs (Refer to
#93 Menu Mode Programming
in
the
Programming Guide
).
NOTE: Field
✳
15 must be programmed with the
partition number the remote sounder will
duplicate
Connect the Amseco piezo between the panel's auxiliary
power and the J7 connector trigger output as shown in
the Remote Keypad Sounding Connections
Figure 3-22
.
1 2
3
4
5
6
7
8
9
GRAY
YELLOW
WHITE
RED
GREEN
BROWN
BLUE
BLACK
GROUND
OUT 1
GROUND
OUT 2
GROUND
OUT 3
GROUND
OUT 4
J7 CONNECTOR
IF USED.
1. OUT 1 IS NO LONGER
USABLE FOR OPEN/CLOSE
OR GROUND START (SEE
FIELD 1*46).
2. OUT 2, 3, 4 CAN STILL BE
USED TO PROVIDE ALARM
STATUS INDICATIONS OR
TO OPERATE A KEYSWITCH
(SEE FIELD *15).
N/U
4142TR CABLE
BLACK
–
AMSECO PAL-328N
PIEZO SOUNDER
+
RED
TO AUX POWER +
TERMINAL 6
(10mA CURRENT DRAIN)
Figure 3-22. Remote Keypad Sounding
Connections
Installing a Remote Keyswitch
If using an optional remote keyswitch for remote
arming and disarming of the system, its switch must be
connected to Zone 7 and its Ready and Armed status
LEDs must be connected to the trigger outputs and
programmed in order to become operational.
Note that a zone 7 keyswitch may be used in
one partition only and Zone 7 is no longer
available as a protection zone.
A momentary short across zone 7 will arm the partition
in the "AWAY" mode. If the short is held for more than
3 seconds, the partition will arm in the "STAY" mode.
After the partition has been armed, the next time Zone
7 is shorted, the partition disarms.
1.
Connect the 4146 keyswitch's normally open
momentary switch to Zone 7.
2.
Connect a 2k EOL resistor across the switch
regardless of whether or not zones 2-8 are selected
to use EOL resistors.
3.
Connect the keyswitch Armed and Ready LEDs to
the J7 connector as shown.
4.
Connect an optional closed circuit tamper switch
(ex. No. 112) in series with zone 7.
5.
Assign the keyswitch to its appropriate partition in
program field *15. Enable open/close reporting
(user #0) for the keyswitch in field *40 (if desired).
NOTE:
When the keyswitch is
removed from the wall, the
tamper switch will open causing
a fault (trouble or alarm) on
zone 7 and causing the panel
to disable keyswitch operation
until the partition is disarmed
from a keypad.
RED
820ohms
YELLOW
RED
(ARMED)
BLACK
820ohms
WHITE
GREEN
(READY)
BROWN
BROWN
BLUE
BLUE
LOCK SWITCH
(NORMALLY OPEN)
2K EOLR
TAMPER SWITCH
TO AUX POWER
(TERMINAL 6)
TO J7/OUT 2
TO ZONE 7(+)
(TERMINAL 20)
TO ZONE 7(– )
(TERMINAL 19)
TO J7/OUT 4
BROKEN LINES REPRESENT
INSTALLER WIRING CONNECTIONS
Figure 3-23. Remote Keyswitch Wiring
LED Indications
Green Red
Meaning
Off
Off
Disarmed & Not Ready
On
Off
Disarmed & Ready
Off
On Steady
Armed Away
Off
Slow Flash
Armed Stay
Off
Rapid Flash
Alarm Memory
Keyswitch By Partition Configuration
In addition to being able to support a 4146 keyswitch on
zone 7 of the control, you can add one keyswitch per
partition via the use of a DPST or a DPDT keyswitch,
wherein the key is removable in two positions: AWAY
and OFF (disarm).
Содержание ADEMCO VISTA-120
Страница 2: ...ii ...
Страница 18: ...VISTA 120 Installation and Setup Guide 2 8 ...
Страница 70: ...VISTA 120 Installation and Setup Guide 5 16 ...
Страница 88: ...VISTA 120 Installation and Setup Guide 7 4 ...
Страница 90: ...VISTA 120 Installation and Setup Guide 8 2 ...
Страница 100: ...VISTA 120 Installation and Setup Guide A 2 ...
Страница 104: ......
Страница 106: ......
Страница 113: ......