HLP-NV Series
HLP-NV Series
-
88
-
16-6* Inputs and Outputs
Parameters for reporting the digital and analog IO ports.
●
Function:
View signal states from active digital inputs.
C16.60 Digital Input RUN,F/R,RST,EMS Default setting
0
Range
[0 - 1111]
●
Function:
View signal state on Digital Input JOG.
C16.61 Digital Input JOG
Default setting
0
Range
[0 - 1]
●
Function:
View input voltage on analog input terminal.
C16.62 Analog Input VIN (volt)
Default setting 0.00
Range
[0.00 - 10.00 V]
●
Function:
View input current on analog input terminal.
C16.63 Analog Input VIN (current) Default setting 0.00
Range
[0.00 - 20.00 mA]
●
Function:
View actual value at Input AIN either as reference or
protection value.
C16.64 Analog Input AIN
Default setting 0.00
Range
[0.00 - 20.00 mA]
●
Function:
View output current on analog Output AO.
C16.65 Analog Output AON [mA]
Default setting 0.00
Range
[0.00 - 20.00 mA]
●
Function:
View input frequency on pulse input terminal.
C16.68 Pulse Input
Default setting 0Hz
Range
[20 - 5000 Hz]
●
Function:
View relay setting.
C16.71 Relay Output [bin]
Default setting
0
Range
[0 - 1]
●
Function:
View analog or pulse feedback in Hz.
C16.52 Feedback [Unit]
Default setting 0.000
Range
[-4999.000 -4999.000]