HLP-NV Series
HLP-NV Series
-
69
-
●
Function:
This scaling value should correspond to minimum reference
value set in par. C06.14. See also section Reference Handling.
C06.10 Terminal VIN Low Voltage Default setting 0.07V
Range
[0.00 - 9.99V] Enter low voltage value.
●
Function:
This scaling value should correspond to maximum
reference value set in par. C06.15.
C06.11 Terminal VIN High Voltage Default setting 10.00V
Range
[0.10 - 10.00 V] Enter high voltage value.
●
Function:
This reference signal should correspond to minimum
reference value set in par. C03.02.
●
Warning:
The value must be set to min. 2 mA in order to activate the
Live Zero Timeout function in par. C06.01.
C06.12 Terminal VIN Low Current Default setting
0.14
Range
[0.00 - 19.99 mA] Enter low current value.
●
Function:
This reference signal should correspond to the maximum
reference value set in par. C06.15.
C06.13 Terminal VIN High Current Default setting 20.00
Range
[0.10 - 20.00 mA] Enter high current value.
●
Function:
The scaling value corresponding to the low voltage/low
current set in parameters C06.10 and C06.12.
C06.14 Term. VIN Low Ref./Feedb. Value Default setting 0.000
Range
[-4999.000 -4999.000]
Enter analog input scaling value.
●
Function:
The scaling value corresponding to the maximum reference
feedback value set in parameters C06.11 and C06.13.
C06.15 Term. VIN High Ref./Feedb. Value Default setting 50.000
Range
[-4999.000 -4999.000]
Enter analog input scaling value.