Title
Drawing
NO
Area Designer
Instruction Manual
C-41-02495
34
/
51
Table 4.4-2 Parameter setting
Parameter
Description
Motor sync angle
To prevent mutual interference motor synchronize
angle can be set.
Heater
To prevent dew condensation at the time of low
temperature.
Output logic
Inverting outputs logic can be set.
Rain
Used to remove rain and snow
Fog
Used to remove fog.
Sensitivity
Used to remove low reflection object.
Filters
Echo
To judge the first echo or the last echo.
Upper limit
Hysteresis upper limit can be set in the range of
0
~
250[mm]
Hysteresis
Lower limit
Hysteresis lower limit can be set in the range of
0
~
250[mm]
Minimum
detectable size
Width of minimum detectable size can be set in the
range of 10
~
1000[mm].
Limited detection
capacity zone
Limited detection capacity zone can be set in the range
of
60mm
~
3000[mm].