![HOKUYO AUTOMATIC UAM-05LP Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/hokuyo-automatic/uam-05lp/uam-05lp_user-manual_2145000097.webp)
Document No: C-61-00003-3
Tab
Item
Description
Function
Sensing
Check to enable the sensing function
Min detection width
*
1
(mm) 30, 40, 50, 70, 150
Active areas
*
2
: Area 1 to Area 32
Area input delay :30ms (Default), 120ms, 270ms, 1s, 2s
Operation mode : Protection 1 + Warning 1/2, Protection 1, 2
Laser off mode: Disable (Default), Enable
7-Segment display upside down configuration: Disable (Default),
Enable
EDM
Check to enable the EDM function
On delay(ms): 90 (Default), 120, 300
Off delay(ms): 300 (Default), 330, 360
* In dual protection mode, EDM1 and EDM2 can be configured
independently.
Interlock
Check to enable the Interlock function
Start/Restart mode: Manual/Automatic, Manual/Manual
Delay(s): 1(Default) to 6
* In dual protection mode, interlock can be independently configured
for protection zone 1 and protection zone 2.
Reference monitor
Check to enable the Reference monitor function
Tolerance(mm): 100 (Default) to 10000
Response time : 1s or Operating area response time
Muting
Check to enable the Muting function
Muting input sequence:
Protection zone 1:
Muting 1
Muting 2 (Default),
Muting 2
Muting 1
Protection zone 2:
Muting 3
Muting 4 (Default),
Muting 4
Muting 3
Time interval between inputs(s): 1(Default), 3, 5, 10
Max. muting period(min): 1(Default), 6, 12 and Unlimited
Max. override period(min): 1(Default), 6,12
* In dual protection mode, muting can be independently configured for
protection zone 1 and protection zone 2.
Area sequence*
3
Check to enable the Area sequence function
The check box of the area sequence possible area will be valid
The check box for all area will be valid
Master Slave
Check to enable Master Slave function
Current device*
4
: Master, (Default) Slave1, Slave2, Slave3
Slave count: 1 (Default) to 3 (For Master only)
Use own OSSD outputs (For slave only)
Encoder Input
Check to enable the Encoder Input function
Error tolerance: 0 to 80 %
Encoder pulse 1: 50 to 1000 (count/cm)
Encoder pulse 2: 50 to 1000 (count/cm)
Select patterns: Each pattern can be selected from Not Use,
Use as
Static input and Use as Encoder input.
Содержание UAM-05LP
Страница 1: ... Document No C 61 00003 3 ...
Страница 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Страница 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Страница 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Страница 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Страница 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Страница 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Страница 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Страница 153: ... Document No C 61 00003 3 ...