Document No: C-61-00003-3
shows an example of periodical inspection items. It is recommended to perform this inspection at every six
months interval. This inspection should be performed together with the daily inspection.
Table 8-4 Periodical inspection list example
No.
Check item
Condition
Remark
Yes
No
1
Screws are tightly fastened
2
No displacement from the original mounting position
3
No scratch or crack on the optical window
4
Screws of the optical window are tightly fastened
5
No oil, grease or dirt on the optical window
6
No visible damage on UAM
7
Cable connector is in good condition and tightly fastened
8
Area is switched and correctly displayed on UAM when
the input signals are changed according to the area
switching table
9
The OSSD signal switches from ON state to OFF state
when the test piece is placed inside the protection zone
10
The OSSD signal remains in OFF state when the test piece
is moved inside the protection zone
11
The OSSD signal switches from OFF state to ON state
when the test piece is removed from the protection zone
12
If the UAM is in automatic restart mode, OSSD signal
switches from ON-state to OFF-state when the test piece is
placed inside the protection zone and switches from
OFF-state to ON-state when the test piece is removed
13
If UAM is in manual restart mode, OSSD signal switches
from ON-state to OFF-state when the test piece is placed
inside the protection zone and remains in OFF-state when
the test piece is removed
14
If the start interlock function is configured, starting the
UAM without placing the test piece in protection zone
causes the OSSD signal to remain in OFF-state until the
RESET signal is provided
15
If the muting function is configured, UAM terminates the
muting (OSSD switches to OFF-state) when the test piece
is placed inside the protection zone other than the muting
area even though the muting conditions are fulfilled.
16
If the muting function is configured, UAM does not switch
to mute state when the muting input sequence is different
than the specified sequence
17
If the muting function is configured, UAM does not switch
to mute
state when the time interval between two muting
inputs exceeded the specified time interval
18
If the muting function is configured, the override function
is terminated when the override period exceeds the
specified override period
Содержание UAM-05LP
Страница 1: ... Document No C 61 00003 3 ...
Страница 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Страница 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Страница 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Страница 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Страница 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Страница 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Страница 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Страница 153: ... Document No C 61 00003 3 ...