5.4 Limited detection capability zone
The limited detection capability zone is defined as a region between the optical window and start of the
detection zone. The limited detection capability zone of the UAM is 90mm
from the origin of UAM (Figure
5-9). Presence of object with low reflectance may not be detected in this zone.
Figure 5-9
Limited detection capability zone
Measured value will be longer than actual distance of the object if the
background is
highly reflective. Additional distance should be included when
configuring the protection zone.
High reflective background (Ex.: Mirror, corner cube reflector, reflective safety
jacket, road reflector) should be avoided. Reflectance caused by these materials
could lead to false detection in the protection zone.
Verify the configured areas before actual operation.
Failing to comply with the above could lead to critical injury or death.
User should perform risk assessment for possibility of object penetration into
the limited detection capability zone.
Содержание UAM-05LP
Страница 1: ... Document No C 61 00003 3 ...
Страница 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Страница 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Страница 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Страница 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Страница 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Страница 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Страница 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Страница 153: ... Document No C 61 00003 3 ...