![HOKUYO AUTOMATIC UAM-05LP Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/hokuyo-automatic/uam-05lp/uam-05lp_user-manual_2145000039.webp)
Document No: C-61-00003-3
3.11 Area sequence function
Area sequence is a function to monitor sequences of area switching. When this function is activated,
OSSD signal will switch to OFF-state if the switching pattern is other than the configured sequence. This
function prevents the machine to operate with random protection zone.
From each area, switching selection to maximum 31 other areas is possible when configuring the area
sequence. And, it is necessary to specify 1 or more areas to avoid error.
<Area switching sequence>
When area sequence is disabled, UAM can switch from an area to any other areas (Figure 3-24(a) whereas
it can only switch to specified
areas if area sequence is enabled. (Figure 3-24(b)).
Area sequence function is recommended for control systems where switching area sequences can be
configured.
Figure 3-24(a) Operation without area sequence Figure 3-24(b) Operation with area sequence
3.12 Response time
Response times of OSSD signal (Figure 3-25),
OFF response time and ON response time (default
270ms) are configurable individually for each area using the UAM project designer. Response time of the
Warning 1 and Warning 2 will be same as the OSSD response time. Table 3-4 shows the possible
configurable values. In the dual protection mode, it is possible to set a separate response time for each
protection area.
When longer response time is configured, the stability of UAM can be increased. However, longer
response time requires longer safety distance. (Refer to chapter 4). User must perform risk assessment before
configuring the response time. Addition of maximum 1 cycle (30ms) has to be taken into account for the area
switching.
Figure 3-25 Response time
Содержание UAM-05LP
Страница 1: ... Document No C 61 00003 3 ...
Страница 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Страница 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Страница 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Страница 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Страница 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Страница 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Страница 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Страница 153: ... Document No C 61 00003 3 ...