Figure 7-46 Area configured by teaching
When the stop button is clicked, an area is generated by the smallest data recorded. Configured area
will resemble the UAM’s background. (Figure 7-46). When configuring the protection zone, if the
background is not within the maximum detection distance it is set to maximum detection distance of
UAM. In case of warning area, if there is no background within 20m from UAM it will be set to 20m.
After the area is created automatically it can be edited using the drawing tools.
It is also possible to specify the region for generating the area by teaching function. Use the area tools
for this purpose. If specified region does not have any background, area will be generated at the
maximum distance of the specified region.
While using the teaching function, user should confirm that the configured zone
meets the safety requirement.
Distance from area to the background should be in the range of 100mm to 700mm.
If the distance exceeds the above mentioned range, there may be unprotected
hazardous area that could lead to critical injury or death.
Содержание UAM-05LP
Страница 1: ... Document No C 61 00003 3 ...
Страница 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Страница 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Страница 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Страница 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Страница 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Страница 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Страница 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Страница 153: ... Document No C 61 00003 3 ...