Document No: C-61-00003-3
is moved inside the protection zone
3
The OSSD signal switches from OFF state to ON state
when the test piece is removed from the protection zone
4
If the UAM is in automatic restart mode, OSSD signal
switches from ON-state to OFF-state when the test piece is
placed inside the protection zone and switches from
OFF-state to ON-state when the test piece is removed
5
If the UAM is in manual restart mode, OSSD signal
switches from ON-state to OFF-state when the test piece is
placed inside the protection zone and remains in OFF-state
when the test piece is removed
6
If the start interlock function is configured, starting the
UAM without placing the test piece in protection zone
causes the OSSD signal to remain in OFF-state until the
RESET signal is provided
7
If the muting function is configured, UAM terminates the
muting (OSSD switches to OFF-state) when the test piece
is placed inside the protection zone other than the muting
area even though the muting conditions are fulfilled.
8
If the muting function is configured, UAM does not switch
to mute state when the muting input sequence is different
than the specified sequence.
9
If the muting function is configured, UAM does not switch
to mute state when the time interval between two muting
inputs exceeds the specified time interval
10
If the muting function is configured, the override function
is terminated when the override period exceeds the
specified override period
11
If the reference monitoring function is configured,
displacement of the reference boundary structures or UAM
should cause the OSSD to switch to OFF-state when
displacement exceeds the allowable tolerance. This is
applicable especially if the angle of approach exceeds ±30º
from the detection plane
12
If the muting function is configured, UAM terminates the
muting if muting period exceeds the specified maximum
period
13
If the area sequence function is configured, OSSD switches
to OFF-state if area switching sequence is different than
the configured sequence.
8.4 Periodical inspection
Periodical inspection should be performed to ensure the detection capability of UAM. Table 8-4 below
Contamination on the optical window switches the OSSD signal to OFF state.
Содержание UAM-05LP
Страница 1: ... Document No C 61 00003 3 ...
Страница 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Страница 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Страница 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Страница 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Страница 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Страница 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Страница 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Страница 153: ... Document No C 61 00003 3 ...