95
Operation
3.9 Operating in Freezing Conditions
Shutdown
1. Allow the vacuum blower to operate for a
couple of minutes after shutting down the high
pressure and charge water pumps to clear
waste water from hoses and dry out blower
system.
2. Make sure the clean water and debris tanks are
drained immediately at the end of each shift.
3. Once the clean water tank is drained using
the main drain, open winterizing drain valve
mounted on the chassis frame below the water
tanks to drain the equalizing hoses and fittings
to completely drain the system.
4. All system hoses and the blast head assem-
blies should be drained of all water and/or filled
with an anti-freeze solution. (Non alcohol)
5. When winterizing the ultra high pressure
pump, refer to pump manufacturer’s proce-
dures for maintaining equipment in freezing
climates.
6. Open the drain valve at the charge water pump
and allow the hoses and pump to completely
drain. With the valve still open, activate the
pump briefly to pump out any remaining water,
about a cupful. Then close the valve.
7. Pour 2 gallons of anti-freeze into the high pres-
sure pump stuffing box sump so it will drain to
the bilge pump sump system. Allow the bilge
pump to run until anti-freeze is visible at the
bilge pump hose fitting in the debris tank.
8. Drain the vacuum canister immediately at the
end of each shift.
WARNING
TO AvOID SERIOuS DAMAGE TO WATERBLASTING
HYDRAuLIC COMPONENTS WHEN OPERATING IN FREEZING
TEMPERATuRES OR TEMPERATuRES BELOW 60 DEGREES
FAHRENHEIT (16
0
CELSIuS), IT IS NECESSARY TO OPERATE
THE HYDRAuLIC SYSTEM AND OTHER WATERBLASTING
COMPONENTS INCLuDING THE BLOWER AND HIGH
PRESSuRE PuMP, WITH THE ENGINE AT IDLE, uNTIL
THE HYDRAuLIC FLuID REACHES A TEMPERATuRE OF
60 DEGREES FAHRENHEIT (16
0
CELSIuS) OR ABOvE AS
INDICATED ON THE THERMOMETER IN THE RESERvOIR
SIGHT GAuGE.
Typical Clean Water Tank Main Drain Valve
Clean Water Tank Winterizing Drain Valve
Charge Water Pump & Drain Valve
Содержание Stripe Hog SH8000
Страница 1: ...Operations Manual...
Страница 2: ...2...
Страница 6: ...6 NOTES...
Страница 16: ...16 NOTES...
Страница 80: ...80 NOTES...
Страница 166: ...166 NOTES...
Страница 171: ...171 Troubleshooting UHP POWER FRAME...
Страница 172: ...172 Troubleshooting...
Страница 173: ...173 Appendix 2 Tools Spare Parts...
Страница 174: ...174 Tools Spare Parts...
Страница 175: ...175 Appendix 3 Daily Report Pre Op Checklist 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM...
Страница 176: ...176 Daily Report Pre Op Checklist 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 61...
Страница 178: ...178 Spray Bar Nozzle Configuration 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 63 Spray Bar Configuration Charts...
Страница 179: ...179 Spray Bar Nozzle Configuration 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 64...
Страница 180: ...180 Spray Bar Nozzle Configuration 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 65...
Страница 181: ...181 Spray Bar Nozzle Configuration 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 66...
Страница 183: ...183 Spray Bar Nozzle Configuration 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 68 Nozzle Calculation Sheet...
Страница 184: ...184 NOTES...
Страница 191: ......