CTC-CEN Service Manual 07-13 Rev.E
57
Move the blocking plate and push off the cylinder.
Mount the new cylinder.
Install the two front adjustment screws and turn them until end of stroke.
Then turn them back of one turn.
Block the counter nuts.
Install the two screws with springs. Tighten them for about 10mm.
Install the washer and tighten the cylinder adjustment screw: when
the screw will touch the washer turn the screw of two more turns.
Connect the air pressure and the power supply.
For the mechanical adjustment refer to par.8,7.
Check if the machine works fine.
Содержание ATC 900
Страница 2: ...CTC CEN Service Manual 07 13 Rev E 2 B L A N K P A G E ...
Страница 7: ...CTC CEN Service Manual 07 13 Rev E 7 ELECTRIC DIAGRAM ...
Страница 8: ...CTC CEN Service Manual 07 13 Rev E 8 PNEUMATIC DIAGRAMS ...
Страница 117: ...CTC CEN Service Manual 07 13 Rev E 117 300KPa 25KPa 400KPa 25KPa ...
Страница 119: ...CTC CEN Service Manual 07 13 Rev E 119 B L A N K P A G E ...