TO CHECK THE CYLINDER WHEN THE AUTOMATIC TOOL WILL NOT LIFT THE TIRE BEAD
Position the cylinder where it leaks air.
Disconnect the air pipe where there is not any air pressure.
If the air is getting out from the fitting, the
tool cylinder
is leaking air.
If the air is getting out from the fitting, the
control valve
is leaking
air.
TO REPLACE THE CYLINDER:
Disconnect the air pressure and the power supply.
Disconnect the air pipes from the cylinder.
Disconnect the automatic tool cylinder from the its bracket and from the tool.
Mount the new cylinder to upper bracket.
Connect the air pipes to the cylinder.
Plug the machine to the air pressure and power supply.
Connect the automatic tool cylinder to the tool.
Perform the adjustment of the connection automatic tool – cylinder following par. 8.2.
Check if the machine works fine.
7.10 AUTOMATIC TOOL CYLINDER VALVE # EAA0328G73A: CHECK AND
REPLACEMENT
:
30’
: 3mm allen key,5,5 and 22mm end key.
: Defective valve may cause the following malfunction:
1.
Air leaking from the valve.
2.
The cylinder would not lift the tire bead.
TO CHECK THE VALVE:
Check the valve following Paragraph 7.8.
TO REPLACE THE VALVE
:
Disconnect the air pressure and the power supply.
Содержание ATC 900
Страница 2: ...CTC CEN Service Manual 07 13 Rev E 2 B L A N K P A G E ...
Страница 7: ...CTC CEN Service Manual 07 13 Rev E 7 ELECTRIC DIAGRAM ...
Страница 8: ...CTC CEN Service Manual 07 13 Rev E 8 PNEUMATIC DIAGRAMS ...
Страница 117: ...CTC CEN Service Manual 07 13 Rev E 117 300KPa 25KPa 400KPa 25KPa ...
Страница 119: ...CTC CEN Service Manual 07 13 Rev E 119 B L A N K P A G E ...