CTC-CEN Service Manual 07-13 Rev.E
40
11. Acquire the position by pressing shortly the button SW2.
Now the LEDs 4 and 5 will remain turned on to show that
the acquiring of calibration points is done.
12 Press and hold SW2 to confirm and store the calibration. LEDs 4 and 5 will turn off and 2 further beeps will be
emitted to indicate the calibration is completed. Now the machine is ready to operate.
13 Turn off the machine.
14 Mount the cover to the electric box.
15 It is allowed to escape the calibration at any time by pressing the button SW4.
Содержание ATC 900
Страница 2: ...CTC CEN Service Manual 07 13 Rev E 2 B L A N K P A G E ...
Страница 7: ...CTC CEN Service Manual 07 13 Rev E 7 ELECTRIC DIAGRAM ...
Страница 8: ...CTC CEN Service Manual 07 13 Rev E 8 PNEUMATIC DIAGRAMS ...
Страница 117: ...CTC CEN Service Manual 07 13 Rev E 117 300KPa 25KPa 400KPa 25KPa ...
Страница 119: ...CTC CEN Service Manual 07 13 Rev E 119 B L A N K P A G E ...