APPENDIX PARAMETER OBJECT LISTS
37
Function
Inst
Attr
Size
Monitoring/Setting Range
Magnifi-
cation
Access
rule
Com-
mand
Multi-Speed 7 (Param82)
1
127
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A027
Multi-Speed 8 (Param83)
1
128
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A028
Multi-Speed 9 (Param84)
1
129
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A029
Multi-Speed 10 (Param85)
1
130
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A030
Multi-Speed 11 (Param86)
1
131
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A031
Multi-Speed 12 (Param87)
1
132
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A032
Multi-Speed 13 (Param88)
1
133
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A033
Multi-Speed 14 (Param89)
1
134
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A034
Multi-Speed 15 (Param90)
1
135
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A035
Jogging Frequency (Param91)
1
138
2
“Start Frequency” to 9.99(Hz)
100
Get/Set
A038
Jog StopMode Sel (Param92)
1
139
1
00(Free run)/01(Deceleration)/
02(DC Braking)/03(R-Free run)/
04(R-Deceleration)/
05(R-DC Braking)
1
Get/Set
A039
Torque Boost Sel (Param93)
1
141
1
00(Manual)/01(Automatic)
1
Get/Set
A041
2ndTrq-Boost Sel (Param333)
2
141
1
00(Manual)/01(Automatic)
1
Get/Set
A241
TorqueBoostValue (Param94)
1
142
1
0.0 to 20.0(%)
10
Get/Set
A042
2ndTrqBoostValue (Param334)
2
142
1
0.0 to 20.0(%)
10
Get/Set
A242
3rdTrqBoostValue (Param368)
3
142
1
0.0 to 20.0(%)
10
Get/Set
A342
TorqueBoostPoint (Param95)
1
143
2
0.0 to 50.0(%)
10
Get/Set
A043
2ndTrqBoostPoint (Param335)
2
143
2
0.0 to 50.0(%)
10
Get/Set
A243
3rdTrqBoostPoint (Param369)
3
143
2
0.0 to 50.0(%)
10
Get/Set
A343
Control Select (Param96)
1
144
1
00(Constant torque)/01(Reduced
torque)/02(Free setting V/f)/03(SLV
control)/04(0Hz-SLV control)/
05(Sensoring vector control)
1
Get/Set
A044
2ndControlSelect (Param336)
2
144
1
00(Constant torque)/
01(Reduced torque)/
02(Free setting V/f)/
03(SLV control)/
04(0Hz-SLV control)
1
Get/Set
A244
3rdControlSelect (Param370)
3
144
1
00(Constant torque)/
01(Reduced torque)
1
Get/Set
A344
Out-Voltage Gain (Param97)
1
145
1
20 to 100 (%)
1
Get/Set
A045
Voltage compensation gain
setting for automatic torque
boost, 1st motor (Param393)
1
146
2
0 to 255
1
Get/Set
A046
Voltage compensation gain
setting for automatic torque
boost, 2nd motor (Param394)
2
146
2
0 to 255
1
Get/Set
A246
Slippage compensation gain
setting for automatic torque
boost, 1st motor (Param395)
1
147
2
0 to 255
1
Get/Set
A047
Slippage compensation gain
setting for automatic torque
boost, 2nd motor (Param396)
2
147
2
0 to 255
1
Get/Set
A247
DC Brake Enable (Param98)
1
151
1
00(Invalid)/01(Valid)/
02(Set Frequency Only)
1
Get/Set
A051
DC Br Start Freq (Param99)
1
152
2
0.00 to 400.00(Hz)
100
Get/Set
A052
DC Br Wait Time (Param100)
1
153
1
0.0 to 5.0(s)
10
Get/Set
A053
DC Brake Power (Param101)
1
154
1
0 to 100(%) (~55KW)
0 to 80(%) (75~132KW)
1
Get/Set
A054
DC Brake Time (Param102)
1
155
2
0.0 to 60.0(s)
10
Get/Set
A055
DC Brake ModeSel (Param103)
1
156
1
00(Edge)/01(Level)
1
Get/Set
A056
DCBrPowerAtStart (Param104)
1
157
1
0 to 100(%) (~55KW)
0 to 80(%) (75~132KW)
1
Get/Set
A057
DCBrTime AtStart (Param105)
1
158
2
0.0 to 60.0(s)
10
Get/Set
A058
DCBr CarrierFreq (Param106)
1
159
1
0.5 to 15.0(kHz) (~55KW)
0.5 to 10.0(kHz) (75~132KW)
10
Get/Set
A059
Upper Freq Limit (Param59)
1
161
4
0.00, “Lower Freq Limit” to
“Max Frequency”(Hz)
100
Get/Set
A061
2ndUpperFRQLimit (Param329)
2
161
4
0.00, “2ndLowerFRQLimit” to
“2
nd
Max Frequency” (Hz)
100
Get/Set
A261