APPENDIX PARAMETER OBJECT LISTS
36
Function
Inst
Attr
Size
Monitoring/Setting Range
Magnifi-
cation
Access
rule
Com-
mand
BRD load factor monitoring
(Param390)
1
175
2
0.0 to 100.0(%)
10
Get
d103
Electronic thermal overload
monitoring (Param391)
1
176
2
0.0 to 100.0(%)
10
Get
d104
Frequency Setting (Param60)
1
159
4
0.00 to 400.00(Hz)
100
Get/Set
F001
Accel Time 1 (Param61)
1
160
4
0.01 to 3600.00(s)
100
Get/Set
F002
2nd Accel Time 1 (Param330)
2
160
4
0.01 to 3600.00(s)
100
Get/Set
F202
3rd Accel Time 1 (Param365)
3
160
4
0.01 to 3600.00(s)
100
Get/Set
F302
Decel Time 1(Param62)
1
161
4
0.01 to 3600.00(s)
100
Get/Set
F003
2nd Decel Time 1(Param331)
2
161
4
0.01 to 3600.00(s)
100
Get/Set
F203
3rd Decel Time 1 (Param366)
3
161
4
0.01 to 3600.00(s)
100
Get/Set
F303
Direction Setting (Param63)
1
162
1
00(Forward)/01(Reverse)
1
Get/Set
F004
Support service
Service name
Code
Get_Attribute_Single
H’0E
Set_Attribute_Single
H’10
(2) Extend Group A object Class ID=101
Function
Inst
Attr
Size
Monitoring/Setting Range
Magnifi-
cation
Access
rule
Com-
mand
Freq-Setting Sel (Param64)
1
101
1
00(Volume)/01(Terminal)/
02(Operator)/03(RS485)/
04(Option1)/05(Option2)/
06(Pulse-string input)/
07(Easy Sequence)/
10(Operation Function result)
1
Get/Set
A001
Operating Mode Sel (Param65)
1
102
1
01(Terminal)/02(Operator)/
03(RS485)/04(Option1)/
05(Option2)
1
Get/Set
A002
Base Frequency (Param56)
1
103
2
30 to “Max Frequency” (Hz)
1
Get/Set
A003
2nd Base Frequency (Param327)
2
103
2
30 to “2nd Max Frequency” (Hz)
1
Get/Set
A203
3rd Base Frequency (Param364)
3
103
2
30 to “3rd Max Frequency” (Hz)
1
Get/Set
A303
Max Frequency (Param55)
1
104
2
30 to 400(Hz)
1
Get/Set
A004
2nd Max Frequency (Param326)
2
104
2
30 to 400(Hz)
1
Get/Set
A204
3rd Max Frequency (Param363)
3
104
2
30 to 400(Hz)
1
Get/Set
A304
AT Function Sel (Param66)
1
105
1
00(O/OI)/01(O/O2)/03(OI/VR)/
04(O2/VR)
1
Get/Set
A005
O2 Function Sel (Param67)
1
106
1
00(Invalid)/01(O/OI-no reverse)/
02(O/OI-reverse)/03(02Invalid)
1
Get/Set
A006
O Start Freq Set (Param68)
1
111
4
0.00 to 400.00(Hz)
100
Get/Set
A011
O End Freq Set (Param69)
1
112
4
0.00 to 400.00(Hz)
100
Get/Set
A012
O Start Rate (Param70)
1
113
1
0 to “O End Rate” (%)
1
Get/Set
A013
O End Rate (Param71)
1
114
1
“O Start Rate” to 100(%)
1
Get/Set
A014
O Start Mode Sel (Param72)
1
115
1
00(Set frequency)/01(0Hz)
1
Get/Set
A015
Analog Sampling (Param73)
1
116
1
1 to 31
1
Get/Set
A016
Easy sequence function selection
(Param392)
1
117
1
00(Invalid)/01(Valid)
1
Get/Set
A017
Multi-Speed Mode (Param74)
1
119
1
00(Binary)/01(Bit)
1
Get/Set
A019
Multi-Speed 0 (Param75)
1
120
4
0.00, “Start Frequency” to
“Max Frequency”(Hz)
100
Get/Set
A020
2nd Multi-Speed0 (Param332)
2
120
4
0.00, “Start Frequency” to
“2nd Max Frequency”(Hz)
100
Get/Set
A220
3rd Multi-Speed0 (Param367)
3
120
4
0.00, “Start Frequency” to
“3rd Max Frequency”(Hz)
100
Get/Set
A320
Multi-Speed 1 (Param76)
1
121
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A021
Multi-Speed 2 (Param77)
1
122
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A022
Multi-Speed 3 (Param78)
1
123
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A023
Multi-Speed 4 (Param79)
1
124
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A024
Multi-Speed 5 (Param80)
1
125
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A025
Multi-Speed 6 (Param81)
1
126
4
0.00, “Start Frequency” to
“n-th Max Frequency”(Hz)
100
Get/Set
A026