Using the Front Panel Keypad
Front Panel Introduction
Please take a moment to familiarize yourself with the keypad layout shown in the figure
below. These are the visible controls and indicators when the front panel door is closed.
The display is used in programming the inverter’s parameters, as well as monitoring
specific parameter values during operation. Many functions are applicable only during
the initial installation, while others are more useful for maintenance or monitoring.
Parameter Editing Controls
Now, open the front panel (half-door) for
second-level access to reveal additional operator
keys for parameter editing as shown to the right.
In normal operation after installation, parameter
editing is unnecessary, so these controls are
hidden from view. The front panel controls and
indicators are described as follows:
•
Run/Stop LED
- ON when the inverter output
is ON and the motor is developing torque
(Run Mode), and OFF when the inverter
output is OFF (Stop Mode).
•
Program/Monitor LED
- This LED is ON
when the inverter is ready for parameter editing (Program Mode). It is OFF when the
parameter display is monitoring data (Monitor Mode).
•
Run Key Enable LED
- is ON when the inverter is ready to respond to the Run key,
OFF when the Run key is disabled.
•
Run Key
- Press this key to run the motor (the Run Enable LED must be ON first).
Parameter F_04, Keypad Run Key Routing, determines whether the Run key generates
a Run FWD or Run REV command.
•
Stop/Reset Key
- Press this key to stop the motor when it is running (uses the
programmed deceleration rate). This key will also reset an alarm that has tripped.
•
Potentiometer
- Allows an operator to directly set the motor speed when the potenti-
ometer is enabled for output frequency control.
•
Potentiometer Enable LED
- ON when the potentiometer is enabled for value entry.
Hz
POWER
A
RUN
PRG
RUN
STOP
RESET
MIN
MAX
HITACHI
5 0.0
Parameter Display
Run/Stop LED
Program/Monitor LED
Run Key Enable LED
Run Key
Stop/Reset Key
Power LED
Display Units
Hertz / Amperes LEDs
Potentiometer Enable LED
Potentiometer
Function
Key
Up/Down
Keys
Store
Key
Hz
POWER
A
RUN
PRG
RUN
STOP
RESET
MIN
MAX
HITACHI
FUNC.
STR
1
2
5 0.0
Содержание L100 Series
Страница 145: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 5 5 ...
Страница 168: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 176: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 B ...
Страница 183: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 6 C ...
Страница 186: ...CE EMC Installation Guidelines Appendix C C 4 L1 L2 L3 PE M 3 L100 inverter with footprint type filter ...
Страница 187: ...L100 Inverter Appendix C C 5 L1 L2 L3 PE L100 inverter with book type filter M 3 ...