Parameter Settings for Keypad Entry
Appendix B
B–4
A_38
Jog frequency setting
1.0
1.0
1.0
A_39
Jog stop mode
00
00
00
A_41
Torque boost method selection
00
00
00
A_42
Manual torque boost value
11
11
11
A_43
Manual torque boost frequency
adjustment
10.0
10.0
10.0
A_44
V/f characteristic curve selection
00
00
00
A_45
V/f gain setting
100
100
100
A_51
DC braking enable
00
00
00
A_52
DC braking frequency setting
0.5
0.5
0.5
A_53
DC braking wait time
0.0
0.0
0.0
A_54
DC braking force during deceler-
ation
0
0
0
A_55
DC braking time during decelera-
tion
0.0
0.0
0.0
A_61
Frequency upper limit setting
0.0
0.0
0.0
A_62
Frequency lower limit setting
0.0
0.0
0.0
A_63,
A_65,
A_67
Jump (center) frequency setting
0.0
0.0
0.0
A_64,
A_66,
A_68
Jump (hysteresis) frequency
width setting
0.5
0.5
0.5
A_71
PID Enable
00
00
00
A_72
PID proportional gain
1.0
1.0
1.0
A_73
PID integral time constant
1.0
1.0
1.0
A_74
PID derivative gain
0.0
0.0
0.0
A_75
PV scale conversion
1.00
1.00
1.00
A_76
PV source setting
00
00
00
A_81
AVR function select
02
00
02
A_82
AVR voltage select
230/400
230/460
200/400
A_92
Second acceleration time setting
15.0
15.0
15.0
A_93
Second deceleration time setting
15.0
15.0
15.0
“A” Group Parameters
Default Setting
User
Setting
Func.
Code
Name
-FE
(Europe)
-FU
(USA)
–FR
(Japan)
Содержание L100 Series
Страница 145: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 5 5 ...
Страница 168: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 176: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 B ...
Страница 183: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 6 C ...
Страница 186: ...CE EMC Installation Guidelines Appendix C C 4 L1 L2 L3 PE M 3 L100 inverter with footprint type filter ...
Страница 187: ...L100 Inverter Appendix C C 5 L1 L2 L3 PE L100 inverter with book type filter M 3 ...