“C” Group: Intelligent Terminal Functions
Configur
ing
Dr
iv
e P
a
ra
m
e
ters
3–36
Output Terminal Configuration
The inverter provides configuration for logic (discrete) and analog outputs, shown in the
table below.
The output logic convention is programmable for terminals [11] and [12]. The open-
collector output terminals [11] and [12] default to normally open (active low), but you
can select normally closed (active high) for these terminals in order to invert the sense of
the logic. You can invert the logical sense of the alarm relay output as well.
“C” Function
Run
Mode
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
Units
C_21 Terminal [11] function
Select terminal [11] function,
6 options (see next section)
✘
01
[FA1]
01
[FA1]
01
[FA1]
—
OUT-TM 1 FA1
C_22 Terminal [12] function
Select terminal [12] function,
6 options (see next section)
✘
00
[RUN]
00
[RUN]
00
[RUN]
—
OUT-TM 2 RUN
C_23 [FM] signal selection
Select terminal [FM] function,
3 options (see next section)
✘
00
[A–F]
00
[A–F]
00
[A–F]
—
MONITOR A-F
“C” Function
Run
Mode
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
Units
C_31 Terminal [11] active
state (–FU)
Select logic convention, two
option codes:
00 ...normally open [NO]
01 ...normally closed [NC]
✘
—
00
—
—
OUT-TM O/C-1 NO
Reserved (–FE / –FR)
(reserved) DO NOT EDIT
✘
00
—
00
—
(not displayed)
C_32 Terminal [12] active
state (–FU)
Select logic convention, two
option codes:
00 ...normally open [NO]
01 ...normally closed [NC]
✘
—
00
—
—
OUT-TM O/C-2 NO
Terminal [11] active
state (–FE / –FR)
(reserved) DO NOT EDIT
✘
00
—
00
—
OUT-TM O/C-1 NO
C_33 Alarm relay active state
Select logic convention, two
option codes:
00 ...normally open [NO]
01 ...normally closed [NC]
✘
01
01
01
—
OUT-TM O/C-RY NO
Содержание L100 Series
Страница 145: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 5 5 ...
Страница 168: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 176: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 B ...
Страница 183: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 6 C ...
Страница 186: ...CE EMC Installation Guidelines Appendix C C 4 L1 L2 L3 PE M 3 L100 inverter with footprint type filter ...
Страница 187: ...L100 Inverter Appendix C C 5 L1 L2 L3 PE L100 inverter with book type filter M 3 ...