5.1.3 Installation / Calibration Hardwired
Attach the supplied angle sensor mounting plate to the left side of the boom. Note the orientation of
the plate from the photo below. If you are going to weld the plate to the boom, remove the angle
sensor from the plate. Do not weld near the angle sensor. It will be damaged by welding.
Install the angle sensor to the plate with #6-32 screws and washers.
Clamp the cable with the supplied clamp and #6-32 screw and washers.
Route the cable from the boom to the console and insert the connector. Loop any extra cable length
and store in a safe location.
Hardwired (HIRSCHMANN)
This is the setup for the standard Hirschmann angle sensor. This angle sensor has a digital output.
The angle sensor must be previously installed.
Use the setup screens to add the angle sensor to the system.
Select the "HIRSCHMANN" from the following menu.
MENU/ SENSORS/ ANGLE/ HARDWIRED/ HIRSCHMANN
SETUP
●
SENSORS
●
ANGLE
NOT INSTALLED
●
HARDWIRED
●
HIRSCHMANN
KRUEGER
RADIO