5.2 Wiring Electric Supply
Wire electric supply with the switch in the pedestal. Terminal L and terminal N are on the switch,
while terminal PE should connect to a ground wire (yellow and green wire).
Note
●
The cable bare part should be no more than 8 mm. It is suggested that you can immerse the
bare part into the liquid tin. If possible, wear an insulation cap at the end of the bare cable.
Make sure there’s no bare copper or cable after the wiring.
●
The Terminal L and the Terminal N cannot be wired reversely. Do not wire the input and output
terminal reversely.
DS-K3B802X Series Swing Barrier User Manual
32