Steps
1. Click Access Control → Advanced Function → Device Parameter to enter Parameter Settings
page.
2. In the device list on the left, select a lane controller and you can edit the lane controller's
parameters on the right.
3. Edit the parameters.
Passing Mode
Select the controller which will control the barrier status of the device.
●
If you select According to DIP Settings, the device will follow the controller's DIP settings to
control the barrier. The settings on the software will be invalid.
●
If you select According to Door's Schedule Settings, the device will follow the schedule
configured in the client software to control the barrier. The DIP settings of the controller
will be invalid.
Enable Free Passing Authentication
After enabling free passing authentication, an alarm will be triggered when the passing
personnel has no permission to pass through.
Opening/Closing Barrier Speed
Set the barrier's opening and closing speed. You can select from 1 to 10. The greater the
value, the faster the speed.
Note
The recommended value is 6.
Alarm Voice Prompt Duration
Set how long the audio will last, which is played when an alarm is triggered.
Note
0 refers to the alarm audio will be played until the alarm is ended.
Temperature Unit
Select the temperature unit that displayed in the device status.
Lightboard Brightness
Set the lightboard brightness.
Barrier Material
Select the material of the barrier gate. You can select the barrier material from the drop-
down list.
Note
The barrier material will affect the device working. Select a correct barrier material or the
barrier may not open.