2. Select an access control device on the left panel, and then click to show the doors or floors of
the selected device.
3. Select a door or floor to show its parameters on the right page.
4. Edit the door or floor parameters.
Note
s
The displayed parameters may vary for different access control devices.
Name
Edit the card reader name as desired.
Exit Button Type
You can set the exit button as remaining closed or remaining open. Usually, it is remaining
open.
Open Duration
After swiping the normal card and relay action, the time for locking the door starts working.
Door Left Open Timeout Alarm
The alarm can be triggered if the door has not been closed in a configured time period. If it is
set as 0, no alarm will be triggered.
Super Password
The specific person can open the door by inputting the super password.
5. Some of the following parameters are not listed in the Basic Information page, click Advanced to
edit the parameters.
Duress Code
The door can open by inputting the duress code when there is duress. At the same time, the
client can report the duress event.
Dismiss Code
Create a dismiss code which can be used to stop the buzzer of the card reader (by entering
the dismiss code on the keypad).
Note
●
The duress code, super code, and dismiss code should be different.
●
The duress code, super password, and the dismiss code should be different from the
authentication password.
●
The length of duress code, super password, and the dismiss code is according the device,
usually it should contains 4 to 8 digits.
6. Click OK.
7. Optional: Click Copy to , and then select the door(s) to copy the parameters in the page to the
selected doors(s).