6. Power on the device again.
Note
For details about the DIP switch value and meaning, see DIP Switch Description.
The barrier will open automatically and turns back to the closed position. At this circumstance,
the device enters the normal mode.
4.2 Pair Keyfob (Optional)
Pair the remote control to the device through DIP switch to open/close the barrier remotely.
Before You Start
Ask our technique supports or sales and purchase the keyfob.
Steps
1. Power off the turnstile.
2. Set the No.4 switch of the 8-digit DIP Switch on the main control board according to the figure
below.
3. Power on the turnstile and it will enter the keyfob pairing mode.
4. Hold the Close button for more than 10 seconds.
The keyfob's indicator of the will flash twice if the pairing is completed.
5. Set the DIP switch as OFF, and reboot the turnstile to take effect.
Note
• You can also pair the keyfob via the client software. For details, see Managing Keyfob in User
Manual of iVMS-4200 AC Client Software.
• Only one turnstile can pair the keyfob. If multiple turnstiles are in the pairing mode, the
keyfob will select only one of them to pair.
• For details about DIP switch value and meaning, see DIP Switch .
4.3 Initialize Device
Steps
1. Remove the jumper cap of initialization pin on the main control board.
DS-K3B501S Series Swing Barrier User Manual
24
Содержание DS-K3B501S Series
Страница 1: ...DS K3B501S Series Swing Barrier User Manual ...
Страница 30: ...Entering Wiring Exiting Wiring DS K3B501S Series Swing Barrier User Manual 17 ...
Страница 32: ...Figure 2 8 Fire Alarm Module Wiring DS K3B501S Series Swing Barrier User Manual 19 ...
Страница 115: ...Figure F 2 Device Command DS K3B501S Series Swing Barrier User Manual 102 ...
Страница 116: ...UD18744B ...