60
S
lideOut
S
yStem
Remove any obstructions before proceeding.
Error Codes:
Refer to error codes explained previously along with instructions on how to locate the inwall
slide controller.
Low Voltage:
The inwall slide controller is capable of operating the room with as little as 8 volts. But
at these lower voltages the amperage requirement is greater. Check the voltage at the
controller. If voltage is lower than 11 volts, it is recommended that the battery be placed on
a charger until it is fully charged. It may be possible to “jump” the RV battery temporarily
to extend or retract the room. Consult Customer Service before attempting to “jump” the
auxiliary battery.
Only 1 Side Moving:
The inwall room slide has a separate motor to operate each side of the room. Does only 1
side of the room move a short distance (2 to 4 inches) and stop? Will Non-moving side move
with help? If only 1 side of the room is moving, then with another person’s assistance press
the switch to extend or retract the room while pushing the non-moving side in the appropriate
direction. On larger rooms it may be necessary to have 2 or more people pushing the room.
Non-moving side moved manually:
Try to push the non-moving side in and out. If a motor shaft has broken then it will be
possible to move that side of the room several inches by hand. Larger rooms may require
several people to push.
Debris in the rack:
Check all 4 gear racks on the side of the room for debris.
Do the status LEDs light?
Locate the slide controller for the slideout in question. When the room slideout direction
switch is actuated, do the status LEDs light up. Check this in both the extend and retract
modes.
Manual override for the inwall slideout
The slideout system comes with an “electronic” manual override. In event the slide out
does not extend or retract follow these steps to override the system which should allow the
slideout to be retracted.
1. Locate the slideout system controllers. There should be one for each slideout on the
recreation vehicle. They are typically located in the basement compartment in the
forward section of the recreation vehicle, either on the forward wall or on the ceiling.
In some models they may be behind a cargo lined panel.
2. The controller that has malfunctioned should have a flashing red LED indicating a hall
signal fault (will flash 8 or 9 times).
3. Press the “mode button” six times quickly, then press a seventh time and hold for
NOTE:
Fuses for the slideouts can be found in the load center and
may be designated as auxiliary or slideout motor.
Содержание RIDGE RV
Страница 1: ...2017 OWNER S MANUAL TOY HAULER 0276622 2017 PRINTED ON RECYCLED PAPER ...
Страница 2: ......
Страница 8: ...2 ...
Страница 20: ...14 Warranty Service Notes ...
Страница 62: ...56 Vehicle Operation Notes ...
Страница 74: ...68 Slideout System Notes ...
Страница 98: ...92 Fuel Propane System Notes ...
Страница 122: ...116 Plumping System Notes ...
Страница 126: ...120 Heating Cooling Notes ...
Страница 132: ...126 Appliances Notes ...
Страница 146: ...140 Exterior Notes ...
Страница 152: ...146 Travel Camping Storage Checklists Service Date Mileage Work Performed Performed By Notes ...
Страница 153: ...147 Travel Camping Storage Checklists Notes ...
Страница 154: ...148 Travel Camping Storage Checklists Notes ...