Operation of the water heater at high altitudes may require derating. If the water heater is
not properly derated, lack of sufficient oxygen for combustion may produce improper burner
operation. Pilot outage caused by burner lift-off or sooting from a yellow burner may occur,
indicating the possibility of carbon monoxide.
You may also notice a lack of efficiency in heating the water because of incomplete
combustion of the burner at these higher altitudes.
Consult with the local propane company, your dealer or the water heater manufacturer for
proper derating of the water heater. Change out of the orifice (derating) should be done by
the dealer or a qualified service agency.
Pressure & temperature relief valve
The temperature and pressure relief valve is designed to open if the temperature of the water
within the heater reaches 120° F, or if the water pressure in the heater reaches 150 pounds.
When this pressure is reached, the pressure relief valve will open and water will drip from
the valve.
This “weeping” or dripping will continue until the pressure is reduced to below 150 pounds,
and the valve closes. This condition is normal and does not indicate a defective relief valve.
One way to reduce the frequency of this occurrence is to maintain an air pocket at the top
of the water heater tank. This air pocket will form in the tank by design; however, it will be
reduced over time by the everyday use of your water heater. To replenish this air pocket:
1. Turn off the water heater.
2. Turn off the cold water supply line.
3. Open a faucet in the recreation vehicle.
4. Pull out the handle of the pressure relief (P&T) valve and allow water to flow from the
valve until it stops.
5. Release the handle on the P&T valve - it should snap closed.
Close the faucet and turn on the cold water supply. As the tank fills, the air pocket will
develop. Repeat this procedure as often as needed to reduce the frequency of the weeping
P&T valve.
Do not place a valve between the pressure and temperature (P&T) valve and
the tank. Do not remove or plug the relief valve under any circumstances.
NOTE:
It is important that once the RV has returned to lower eleva-
tion (below 4500 feet) any high altitude deration or other adjustments
be reversed for proper operation of the water heater
.
Содержание RIDGE RV
Страница 1: ...2017 OWNER S MANUAL TOY HAULER 0276622 2017 PRINTED ON RECYCLED PAPER ...
Страница 2: ......
Страница 8: ...2 ...
Страница 20: ...14 Warranty Service Notes ...
Страница 62: ...56 Vehicle Operation Notes ...
Страница 74: ...68 Slideout System Notes ...
Страница 98: ...92 Fuel Propane System Notes ...
Страница 122: ...116 Plumping System Notes ...
Страница 126: ...120 Heating Cooling Notes ...
Страница 132: ...126 Appliances Notes ...
Страница 146: ...140 Exterior Notes ...
Страница 152: ...146 Travel Camping Storage Checklists Service Date Mileage Work Performed Performed By Notes ...
Страница 153: ...147 Travel Camping Storage Checklists Notes ...
Страница 154: ...148 Travel Camping Storage Checklists Notes ...