23 / 88
en
Rev. 03 / 02.2021
AB3200
Commissioning
Setting up the centrifuge
WARNING
Risk of injury due to parts falling out of the packaging!
When parts fall out of the transport packaging, there is a risk
of crushing injuries to extremities.
−
Observe the warnings for opening the packaging.
−
Only open the packaging at the specified point.
1.
Remove the packaging bands.
2.
Lift up the box and remove the padding.
3.
Remove the accessories.
4.
Set up the device on a stable and flat surface with a suitable number
of helpers. Note the weight of the device.
NOTICE
Check the device for any transport damage before commis-
sioning. Do not put the device into operation if there is trans-
port damage or if moisture has penetrated it.
5.2
Setting up, connecting and switching on the device
Switching off the device with the device switch does not
disconnect this completely from the mains. The device is
completely disconnected from the mains by pulling out the
mains cable. The mains cable must be freely accessible at
all times in order to be able to disconnect the device from
the mains at the power socket or device plug.
Personnel:
■
Authorized skilled personnel with special instruction