T-CONTROL
9
43
Term
Description
Unit
Overview Operation
modes
Selection operation modes:
▪
Heating OFF
The heating system is switched off
▪
Heating time mode:
Heating corresponds to the set heating time
▪
Durable heat:
Constant heat up to required set room temperature or to the
calculated feed flow target temperature
▪
Durable kneeling:
Always heat to the kneeling temperature or during the kneeling time
to the calculated flow must temperature
▪
Remote control mode:
Mode according to the setting of the remote control
Menu "Status"
Status 1
1
2
Flow temperature
Indicates the flow temperature of chosen heating circuit
°C
Back flow temperature
Indicates the back flow temperature of chosen heating circuit
°C
Outside temperature
Display of the actual outside temperature
°C
Room temperature
Setting up required room temperature (15-30).
°C
Room correction
The correction is a factor for influencing or correction of the flow must
temperature:
This value (-5 to +5) gets multiplied by 2 and added to the flow set
temperature
°C
Status 2
1
2
Switching temperature
Indicates the switching temperature (= average daytime temperature). In
general the switching temperature conduces to switch between winter set
temperature and summer set temperature.
°C
Heating circuit mixer
Indicates the state of the heating circuit mixer (OPEN/CLOSE)
-
Heating circuit pump
Indicates the state of the heating circuit pump (ON/OFF)
-
Screed days
Display of the respective screed day (only if screed drying is set)
-
Menu "Settings"
Settings 1
1
2 3
Operation modes
▪
OFF
: The heating system is switched off
▪
Heating time mode
: Heating corresponds to the set heating time
▪
Durable heat
: Constant heat up to required set room temperature or to
the calculated feed flow target temperature.
▪
Durable kneeling
: Always heat to the kneeling temperature or during
the kneeling time to the calculated flow must temperature.
▪
Flow fixed
: During the set heating times the set flow fixed temperature
is kept constant.
▪
Remote control
: Mode according to the setting of the remote control.
▪
Screed drying
: Mode of screed drying. The operation of the screed
drying is described below
-
Содержание pelletstar CONDENSATION 10
Страница 1: ...OPERATING INSTRUCTIONS Pellet boiler pelletstar CONDENSATION 10 60 ...
Страница 20: ...8 Temperature manager 20 Fig 8 6 Example temperature manager when time mode without difference ...
Страница 85: ...Annex 15 85 15 ANNEX 15 1 Additional boiler schematic visualization Hydraulic recommendation 1 ...
Страница 86: ...15 Annex 86 Hydraulic recommendation 2 ...
Страница 87: ...Annex 15 87 15 2 Solar module schematic representation Program 1 ...
Страница 88: ...15 Annex 88 Program 2 ...
Страница 89: ...Annex 15 89 Program 3 ...
Страница 90: ...15 Annex 90 Program 4 ...
Страница 91: ...Annex 15 91 Program 5 ...
Страница 92: ...15 Annex 92 Program 6 ...
Страница 93: ...Notes 16 93 16 NOTES ...