9
T-CONTROL
36
Term
Description
Unit
In- / Outputs
1 2 3 4
5
6 7
Ash discharge
Indicates the state of the central de-ashing system:
If switch on green
➔
Output active.
-
Ash discharge
monitoring
Indicates the state of the sensor of the ash discharge monitoring.
If the indicator lamp lights up alternately during operation, the ash
screw works correct.
-
Fault central de-ashing
system
Display input error central ash discharge.
If the indicator lamp lights up a fault is active.
-
Heat exchanger
cleaning
Indicates the state of the heat exchanger cleaning:
If switch on green
➔
Output active.
-
Magnetic valve
Indicates the state of the magnetic valve:
If switch on green
➔
Output active.
-
Fault E-filter
Indicates the output of the E-filter
-
Fluegas-recirculation
flap
Indicates the output of the fluegas-recirculation flap
%
In- / Outputs
1 2 3 4 5
6
7
Back flow pump
Displays the state of the backflow pump:
If switch on green
➔
Output active.
%
Back flow mixer open
Displays the state of the Backflow mixer:
If switch on green
➔
Output active.
l/h
Back flow mixer close
Displays the state of the Backflow mixer:
If switch on green
➔
Output active.
-
Output temperature
monitoring control
(TÜB)
Displays the state of the Output temperature monitoring control:
If switch on green
➔
Output active.
-
Temp. monitoring
control storage room
Displays the state of the Output temperature monitoring control storage
room:
If the indicator lamp lights up, the maximum storage room temperature
is exceeded (the storage room temperature control sensor is active).
-
Sum annoyance
Displays the condition of the Sum annoyance:
If switch on green
➔
Output active (active fault).
-
Operating alarm unit
Displays the condition of the Operating alarm unit:
If switch on green
➔
Output active.
-
In- / Outputs
1 2 3 4 5 6
7
STL
Indicates the input of the safety temperature limiter (STL): If the
indicator lamp lights up, the STL has tripped.
-
Burner stop
Indicates the input burner stop. When the control lamp is lit, the system
has been stopped via the digital input (no burner release)
-
Additional input
Indicates the state of the additional input.
▪
If the indicator lamp lights up, the additional input is active (there is
an error)
At the additional input, the message of an external unit (CO detector,
extinguishing water tank, system pressure monitoring, etc.) can be
detected, for example.
-
Menu
"Operating hours"
Operating hours 1
1
2
Nominal load
Displays system operation hours during nominal load phase (95 -100%)
h
Modulation
Displays system operation hours during modulation phase (94-31%)
h
Part load
Displays system operation hours during part load phase (<30%)
h
Содержание pelletstar CONDENSATION 10
Страница 1: ...OPERATING INSTRUCTIONS Pellet boiler pelletstar CONDENSATION 10 60 ...
Страница 20: ...8 Temperature manager 20 Fig 8 6 Example temperature manager when time mode without difference ...
Страница 85: ...Annex 15 85 15 ANNEX 15 1 Additional boiler schematic visualization Hydraulic recommendation 1 ...
Страница 86: ...15 Annex 86 Hydraulic recommendation 2 ...
Страница 87: ...Annex 15 87 15 2 Solar module schematic representation Program 1 ...
Страница 88: ...15 Annex 88 Program 2 ...
Страница 89: ...Annex 15 89 Program 3 ...
Страница 90: ...15 Annex 90 Program 4 ...
Страница 91: ...Annex 15 91 Program 5 ...
Страница 92: ...15 Annex 92 Program 6 ...
Страница 93: ...Notes 16 93 16 NOTES ...