T-CONTROL
9
33
Term
Description
Unit
Rotation speed
Indicates the actual ID-fan rotation speed
%
Under pressure
Indicates the current under pressure in the burning chamber
Pa
Secondary air flap
Indicates the state of the secondary air flap
%
Status 4
1 2 3
4
Under pressure
correction
Indicates the current under pressure correction factor of the lambda
control
%
Material correction
Indicates the actual material correction of the lambda probe control
-%
Insertion - tact
Indicates the stoker screw (= feeding screw) interval (fuel gets fed to
the burning chamber)
- Interval is set up by the customer service!
0,1s
Insertion - pause
Indicates the stoker screw (= feeding screw) interval (fuel gets not fed
to the burning chamber)
- Interval is set up by the customer service!
0,1s
O2 [%]
Display of the actual O2-content (oxygen content) in the flue gas.
%
CO2 [%]
Display of the actual CO2-content (carbon dioxide content) in the flue
gas.
%
Menu
„Settings“ (system specific)
Settings
1
2 3 4 5
Residual heat
temperature
Setting up the residual heat temperature (20-75) e.g.: minimum boiler
temperature after fuel burnout, when (at the latest) return flow pump gets
turned off.
°C
Control hysteresis
Setting up the control hysteresis (3-20). It is a temperature above which
the required boiler temperature is regulated.
°C
Waiting period
The transfer of the demand to the boiler is delayed by the set time (0-
240).
min
Settings
1
2
3 4 5
Variant 1
If “weather-related performance management" is not activated.
-
Power max
Setting up the maximum boiler power (30-100). Enable boiler power
regulation (limita
tion) (Only if “weather-related performance management"
is not activated.)
%
Variant 2
If “weather-related performance management" is activated.
-
Outside temp. sensor
Selection of the outside temperature sensor
If multiple outside temperature sensors are installed, the desired outside
temp. sensor can be assigned to the chosen heating circuit.
-
Balancing
outside
sensor
Adjusting the balancing of the outside temperature (± 5):
Shows the outside sensor not the correct outside temperature the value
can be adjusted.
°C
Actual
outside
temperature
Indicates the actual outside temperature.
°C
Power at Outside
temperature 1
Setting the maximum output (30-100) of the boiler when the temperature
is below the set outside temperature 1. The boiler output can thus be
regulated depending on the temperature.
%
Outside temperature 1
Setting the temperature (-40 - 20) below which the output is set at outside
temperature 1.
°C
Power at Outside
temperature 2
Maximum boiler output set outside temperature (30-100)
%
Outside temperature 2
Upper temperature of the heating curve (0 - 60)
°C
Содержание pelletstar CONDENSATION 10
Страница 1: ...OPERATING INSTRUCTIONS Pellet boiler pelletstar CONDENSATION 10 60 ...
Страница 20: ...8 Temperature manager 20 Fig 8 6 Example temperature manager when time mode without difference ...
Страница 85: ...Annex 15 85 15 ANNEX 15 1 Additional boiler schematic visualization Hydraulic recommendation 1 ...
Страница 86: ...15 Annex 86 Hydraulic recommendation 2 ...
Страница 87: ...Annex 15 87 15 2 Solar module schematic representation Program 1 ...
Страница 88: ...15 Annex 88 Program 2 ...
Страница 89: ...Annex 15 89 Program 3 ...
Страница 90: ...15 Annex 90 Program 4 ...
Страница 91: ...Annex 15 91 Program 5 ...
Страница 92: ...15 Annex 92 Program 6 ...
Страница 93: ...Notes 16 93 16 NOTES ...