Operation Manual
BinTra
c Operator’s Manual Ver. 3.18 Rev. 1.01
5
Part Number MAN-000004-2
Program Alert Level
(Optional alert relay assembly feature on the BT260)
This procedure adjusts the level that the output (alert) relay is triggered. The output relay has both normally open and
normally closed contacts.
1. Press and hold the LOWER
key for 5 seconds.
2. After 5 seconds, the bar graph and Bin A (or lowest enabled bin) will begin flashing.
3. Press BIN to select the desired bin.
4. Use UPPER
or LOWER
key to adjust alert level.
5. If alert level is set to one of the upper 8 indicators (top half of the bin), alert is configured as a high level alert.
The output relay will trigger when the indicated bin level is at or above this point.
6. If alert level is set to one of the lower 8 indicators (lower half of bin), alert is configured as a low level alert. The
output relay will trigger when the indicated bin level is at or below this point.
7. If alert
point is set below or above the displayable indicators, the bin level display will turn off and the alert will
be disabled for the selected bin.
8. After last selected bin is set, press BIN again to exit programming mode. Otherwise unit will return to Auto
Sequence mode after 5 minutes of no activity (no keystrokes).