Operation Manual
BinTra
c Operator’s Manual Ver. 3.18 Rev. 1.01
12
Part Number MAN-000004-2
Internal Mode Settings
Gain
GAIN is a calculated field that should NOT be changed by the user.
Segmented display:
Serial Number
The serial number is preset during production and should NOT be changed by the user.
Segmented display:
Pulse Value
Sets the number of weight units per pulse when used in conjunction with a HouseLink Digital Interface (HL-10D). Set to
how many pounds or kilograms of weight loss of the combined enabled bins for every pulse output. When set t
o “0”,
pulse output is disabled.
1. Press the BIN key to display and allow editing of programmed value. Select the desired bin.
2. Use the UPPER
key to increase the pulse weight by 1.
3. Use the LOWER key to decrease the pulse weight by 1.
Segmented display:
Reset
Used to reset the BinTrac Indicator to factory defaults.
CAUTION: Resetting the BinTrac Indicator will erase all weight and user configured settings. Make sure to write
down the settings prior to resetting if using this feature.
1. Press the BIN key. All bins will show solid.
2. Press and hold the UPPER
key and LOWER key simultaneously until
‘done’ is displayed.
3. Press the BIN key, then use the UPPER
key or LOWER
key to cycle through to End.
4. Press the BIN key to exit.
Segmented display:
Inter
INTER is a preset field that should NOT be changed by the user.
Segmented display: