System Setup  

The units are easily wired by a qualified technician using standard communication wiring.  See the BinTrac Installation 
Manual for detailed wiring information.  The System setup has two levels of settings: 1) Operation Settings: These are

 

settings that may be changed for normal use by an operator and 2) System Settings: These are a one-time setup 
usually done at the time of installation.

 

Operation Settings 

 
New BinTrac bin weighing system installations require a one-time system configuration procedure before use.  In this 
mode you can configure the number of bins you wish to monitor. 
  

Selecting

 

Bins

 

This procedure will allow you to enable the BinTrac Indicator to only scan and display the weights 
of bins that are connected. 
 

1. 

Ver 3.18 & up (All BT260s and some BT200s)

 - On the BinTrac Indicator, press and 

hold the BIN key until 

 appears, then release the BIN key and 

 will be 

displayed. 
 

Ver 3.17 & below (most BT200s) 

- On the BinTrac Indicator, press and hold the BIN key  

until 

 appears, then release the BIN key.  Press the LOWER 

 key once and 

 will be 

displayed. 
 
All the bin selector indicators will illuminate showing their current status.  If a bin indicator is on steady, it is 
selected as being monitored. If the indicator is flashing, that bin is not being monitored. 
 

2.  Press the BIN key to select the desired bin. 
 
3.  If the indicator is on steady, the bin is being monitored. If it is flashing, the bin is not being monitored. Press the 

UPPER 

 or LOWER   key to toggle bin monitoring on or off. 

 

4.  Repeat steps 2 and 3 for additional bins. After bins A through D have been configured correctly for your 

application, press the BIN key and the unit displays 

.  Press the UPPER 

 key three times until 

 is displayed. 

 

5.  Press the BIN key to exit programming mode and return to bin weighing. Unit will start auto sequencing after 5 

minutes of no activity (no keystrokes). 
 
 
 

Calibrate Bin Empty (Zero) 

This procedure will zero the BinTrac system weight by correcting for the dead-load of the empty bin.  For the most 
accurate zero reading, ensure the bin is empty and free of any additional weight.  
 

1.  Press the BIN key to select the desired bin to zero. 

 

2.  Press both the LOWER

 

 and the UPPER

 

 key and hold for 5 seconds.  While held, the bar graph and bin 

indicators will flash until 5 seconds have passed and the indicated bin level has been zeroed. 

 

3.  Unit returns to Auto Sequence mode after this procedure and will start auto sequencing after

 

5 minutes of no 

activity (no keystrokes). 
 
 
 

Содержание BINTRaC BT200

Страница 1: ...em Operation Manual BT200 BT260 U S Patent No 7 980 129 Patent No 8 581 122 Patent No 8 853 566 U S Patent No 9 310 243 Patent No 9 651 413 Patent No 10 082 421 Canada Patent No 2 822 294 Korea Patent...

Страница 2: ...0 and higher 7 Serial Data Command Set 7 Setup Mode Settings 8 Internal Mode 11 Accessing the Internal mode 11 Navigating Internal mode 11 Selecting an Option in Internal mode 11 Internal 11 Totalizin...

Страница 3: ...s that could result from voids holes in the material Smart Summing Box One Smart Summing Box per bin communicates the current reading on the leg brackets to the BinTrac Indicator BinTrac Power Supply...

Страница 4: ...r indicators will illuminate showing their current status If a bin indicator is on steady it is selected as being monitored If the indicator is flashing that bin is not being monitored 2 Press the BIN...

Страница 5: ...alert level is set to one of the upper 8 indicators top half of the bin alert is configured as a high level alert The output relay will trigger when the indicated bin level is at or above this point 6...

Страница 6: ...elease the BIN key The display will then move to the bin selection as show below Segmented display Ver 3 17 below most BT200s Press and hold the BIN key until is displayed then release the BIN key The...

Страница 7: ...egmented display Serial Data Command Set Poll Command Description and Data Record Format fixed length P Current weight of first enabled bin wwwwwcrlf PP Current weight of all four bins wwwww wwwww www...

Страница 8: ...just this value appropriately IMPORTANT DO NOT change this setting from the default of 3 000 if you are using HerdStar load cells 1 Press the BIN key to select the desired bin 2 Use the UPPER key to i...

Страница 9: ...ts the weight of a full bin This is for calibration of the LED bar graph level The value dictates at what net weight the bar graph will display completely full all 16 LEDs lit 1 Press the BIN key to s...

Страница 10: ...Segmented display Software Version Version 3 0 and higher Displays the BinTrac programmed software version number This number may be required if technical help is needed 1 Press the BIN key to see the...

Страница 11: ...ultiple Summing Boxes V3 03 BIN D Change transmitted weight values from fixed 5 digits to fixed 6 digits Totalizing Multiple Bins For applications which require more than one Smart Summing Box on a bi...

Страница 12: ...ss the BIN key to display and allow editing of programmed value Select the desired bin 2 Use the UPPER key to increase the pulse weight by 1 3 Use the LOWER key to decrease the pulse weight by 1 Segme...

Страница 13: ...Indicator through a series of LED tests Segmented display Year Year is set at the time of production and should NOT be changed Segmented display Month Month is set at the time of production and shoul...

Страница 14: ...corded fill events 5 Press BIN to return to Auto Sequence mode or unit will start auto sequencing after 5 minutes of no activity no keystrokes Display 24 Hour Usage This procedure allows you to view t...

Страница 15: ...mming Boxes to ensure it has not been damaged 5 Disconnect components until the defective component is located that is shorting power a Disconnect Smart Summing Boxes and cycle power b Disconnect 12 a...

Страница 16: ...e of the displayable range 1 Verify programmed settings are correct a Verify Zero calibration is valid and in range b Verify load cell capacity L C Cap has been correctly programmed 2 Open Smart Summi...

Страница 17: ...t was intended for use as a Remote Display and not programmed incorrectly a Bin A LED should be solid in setup menu if unit is intended to be configured as remote display If unit is NOT intended to be...

Страница 18: ...accurate reading or proceed to Comprehensive Load Cell Inspection Procedure Comprehensive Load Cell Inspection Procedure 1 Record Note Current Weight Reading on BinTrac Indicator 2 Disconnect all but...

Страница 19: ...ets forth Buyer s sole and exclusive remedies for any defect in the goods The rights and obligation under this warranty may not be assigned or delegated to a third party by Buyer without the prior wri...

Страница 20: ...the declaration Models PS17 BT260 SSB100 The object of the declaration described above is in conformity with the relevant Union harmonisation legislation Applicable Directives Harmonized Standards or...

Отзывы: