background image

Operation Manual                                                                                                                                                                                                                                         
 

BinTra

c Operator’s Manual Ver. 3.18 Rev. 1.01 

18 

Part Number MAN-000004-2

 

Load Cell Troubleshooting Procedures 

The procedures below outline the steps for identifying and locating a defective load cell.   Procedure 1 is most 
commonly used and quickest, although Procedure 2 can be used for better analysis and for determining even loading 
across all load cells. 
 

1.  Check for cut load cell cables. 
2.  Check connections in summing box. 
3.  Check for debris under bin legs. 
4.  Check for binding between bracket and bin legs. 

Quick Load Cell Inspection Procedure 

1.  Record/Note Current Weight Reading on BinTrac Indicator. 
2.  Disconnect a single load cell from Smart Summing Box. 
3.  Observe for change in weight display.  If weight change is significant and/or more stable, note this load cell as 

possible defect. 

4.  Reconnect load cell if symptoms did not change. 
5.  Repeat for remaining load cells. 
6.  Replace load cell that when disconnected provides the most accurate reading or proceed to Comprehensive 

Load Cell Inspection Procedure. 

Comprehensive Load Cell Inspection Procedure 

1.  Record/Note Current Weight Reading on BinTrac Indicator 
2.  Disconnect all but number one load cell within summing box. 
3.  Record weight reading. 
4.  Disconnect load cell and connect next load cell and repeat for all remaining load cells. 
5.  Review weight readings.   
6.  Variations in readings can be caused by offset loading within bin and/or improper lifting screw tension. 

a.  Inspect loading within bin matches load cell reading variations.   
b.  Examine bracket assembly and lifting screw tension. 

i.  If reading is low and others beside it are high, tighten screw slightly. 

ii.  If reading is high and others beside it are low, loosen screw slightly. 

iii.  If reading is out of range, replace load cell. 

iv.  Repeat individual readings inspection and adjustments return to Step 2. 

7.  Reconnect all load cells except for known defective one. 
8.  Repeat procedure if weight reading is not accurate. 

 
Note:  If a defective load cell is located, by unplugging it, the scale system will continue to function until time is 
available to replace the defective load cell. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание BINTRaC BT200

Страница 1: ...em Operation Manual BT200 BT260 U S Patent No 7 980 129 Patent No 8 581 122 Patent No 8 853 566 U S Patent No 9 310 243 Patent No 9 651 413 Patent No 10 082 421 Canada Patent No 2 822 294 Korea Patent...

Страница 2: ...0 and higher 7 Serial Data Command Set 7 Setup Mode Settings 8 Internal Mode 11 Accessing the Internal mode 11 Navigating Internal mode 11 Selecting an Option in Internal mode 11 Internal 11 Totalizin...

Страница 3: ...s that could result from voids holes in the material Smart Summing Box One Smart Summing Box per bin communicates the current reading on the leg brackets to the BinTrac Indicator BinTrac Power Supply...

Страница 4: ...r indicators will illuminate showing their current status If a bin indicator is on steady it is selected as being monitored If the indicator is flashing that bin is not being monitored 2 Press the BIN...

Страница 5: ...alert level is set to one of the upper 8 indicators top half of the bin alert is configured as a high level alert The output relay will trigger when the indicated bin level is at or above this point 6...

Страница 6: ...elease the BIN key The display will then move to the bin selection as show below Segmented display Ver 3 17 below most BT200s Press and hold the BIN key until is displayed then release the BIN key The...

Страница 7: ...egmented display Serial Data Command Set Poll Command Description and Data Record Format fixed length P Current weight of first enabled bin wwwwwcrlf PP Current weight of all four bins wwwww wwwww www...

Страница 8: ...just this value appropriately IMPORTANT DO NOT change this setting from the default of 3 000 if you are using HerdStar load cells 1 Press the BIN key to select the desired bin 2 Use the UPPER key to i...

Страница 9: ...ts the weight of a full bin This is for calibration of the LED bar graph level The value dictates at what net weight the bar graph will display completely full all 16 LEDs lit 1 Press the BIN key to s...

Страница 10: ...Segmented display Software Version Version 3 0 and higher Displays the BinTrac programmed software version number This number may be required if technical help is needed 1 Press the BIN key to see the...

Страница 11: ...ultiple Summing Boxes V3 03 BIN D Change transmitted weight values from fixed 5 digits to fixed 6 digits Totalizing Multiple Bins For applications which require more than one Smart Summing Box on a bi...

Страница 12: ...ss the BIN key to display and allow editing of programmed value Select the desired bin 2 Use the UPPER key to increase the pulse weight by 1 3 Use the LOWER key to decrease the pulse weight by 1 Segme...

Страница 13: ...Indicator through a series of LED tests Segmented display Year Year is set at the time of production and should NOT be changed Segmented display Month Month is set at the time of production and shoul...

Страница 14: ...corded fill events 5 Press BIN to return to Auto Sequence mode or unit will start auto sequencing after 5 minutes of no activity no keystrokes Display 24 Hour Usage This procedure allows you to view t...

Страница 15: ...mming Boxes to ensure it has not been damaged 5 Disconnect components until the defective component is located that is shorting power a Disconnect Smart Summing Boxes and cycle power b Disconnect 12 a...

Страница 16: ...e of the displayable range 1 Verify programmed settings are correct a Verify Zero calibration is valid and in range b Verify load cell capacity L C Cap has been correctly programmed 2 Open Smart Summi...

Страница 17: ...t was intended for use as a Remote Display and not programmed incorrectly a Bin A LED should be solid in setup menu if unit is intended to be configured as remote display If unit is NOT intended to be...

Страница 18: ...accurate reading or proceed to Comprehensive Load Cell Inspection Procedure Comprehensive Load Cell Inspection Procedure 1 Record Note Current Weight Reading on BinTrac Indicator 2 Disconnect all but...

Страница 19: ...ets forth Buyer s sole and exclusive remedies for any defect in the goods The rights and obligation under this warranty may not be assigned or delegated to a third party by Buyer without the prior wri...

Страница 20: ...the declaration Models PS17 BT260 SSB100 The object of the declaration described above is in conformity with the relevant Union harmonisation legislation Applicable Directives Harmonized Standards or...

Отзывы: