Operation Manual
BinTra
c Operator’s Manual Ver. 3.18 Rev. 1.01
17
Part Number MAN-000004-2
This means that the weight in the bin has exceeded the programmed system capacity by 150% and the system is in an
over-load state.
1. Verify programmed settings are correct
2. Check for physical binding of brackets/hardware
4. Remove the weight from the system and check the condition of each load cell (See
Load Cell
Troubleshooting Procedures
)
This means that the Remote Display has lost communications with the host BinTrac Indicator.
1. Verify unit was intended for use as a Remote Display and not programmed incorrectly
a. Bin A LED should be solid in setup menu if unit is intended to be configured as remote display. If unit is
NOT intended to be a remote display, Bin A LED should be blinking in setup menu (see
Page 7
).
2. Check for broken wires or loose connections
3. Verify wiring is correct between Indicator and Remote Display
This error message indicates that the BinTrac Indicator has been programmed for a pulse output and is unable to
communicate with the HouseLink WP.
1. If system does not have a HouseLink WP, set the
programmable PULSE parameter to “0” (see
Page 12
)
2. Verify HouseLink WP dip switch settings (See HouseLink manual)
3. Check for broken wires or loose connection