Model LVG-102, 103, 104
1-3
Problem
Cause
Correction
POWER SECTION
With power switch in
•
Open circuit
•
Check to see that unit is plugged in
ON position, the fryer
is completely inoperative
•
Check the breaker or fuse
(NO POWER)
at supply box
•
Check voltage at wall receptacle
•
Check MAIN POWER
switch; replace if defective
•
Check cord and plug
•
Reset transformer circuit breaker
•
Blown fuse or tripped
•
Reset breaker or replace fuse
circuit breaker at supply
box or control panel
•
Faulty power switch.
•
Check power switch
•
Faulty cord and plug
•
Check cord and plug
• Check power at receptacle
•
Faulty drain switch
•
Check drain switch
•
Faulty PC Board
•
Check control panel per maintenance
section and replace as needed
•
High limit control switch tripped
•
Let unit cool down (15-20 minutes),
press red reset button under right
side of the controls; if high limit
does not reset, high limit must be
replaced
HEATING OF SHORTENING SECTION
Oil will not heat
July 2010
Содержание LOV LVG-102
Страница 2: ...Model LVG 102 103 104 2...
Страница 21: ...Model LVG 102 103 104 3 6...
Страница 71: ...Model LVG 102 103 104 8 7 1 2 1 3 4 6 5 7 8 9 10 11 12 5 13 14 15 14 17 16 4 Feb 2011...
Страница 89: ...Model LVG 102 103 104 A 2 May 2016...
Страница 90: ...Model LVG 102 103 104 A 3 May 2016...
Страница 91: ...Model LVG 102 103 104 A 4 May 2016...
Страница 92: ...Model LVG 102 103 104 A 5 May 2016...
Страница 93: ...Model LVG 102 103 104 A 6 May 2016...
Страница 94: ...Model LVG 102 103 104 A 7 May 2016...
Страница 95: ...Model LVG 102 103 104 A 8 May 2016...
Страница 96: ...Model LVG 102 103 104 A 9 May 2016...
Страница 97: ...Model LVG 102 103 104 A 10 May 2016...
Страница 98: ...Model LVG 102 103 104 A 11 May 2016...