Model LVG-102, 103, 104
7-16
Checkout (Continued)
11. If control panel still does not display, replace panel with a
known good control panel. If problem follows control
panel, replace panel per paragraph 7-4.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Pull-down control panel to access the desired transformer.
2. Label and remove wires from (AIF) transformer, or
disconnect white connector on the control transformer.
3. Using a 5/16” socket, remove nuts securing the transformer
and pull the transformer from unit.
4. Replace transformer in reverse order.
7-12. TRANSFORMERS
(Continued)
AIF Transformer
Control Transformer Connector
Control Transformer
AIF Transformer
June 2010